Henny Penny OEA/OGA-341 Line under and away from all electrical power wires, Terminals

Page 35

Model OFE/OFG/OEA/OGA-341, 342

2-20. HIGH TEMPERATURE

LIMIT CONTROL (ELECTRIC) (Continued)

 

4.

Straighten the capillary tube, and pull capillary tube through

 

 

the hole in the element hinge, from the rear of the fryer.

 

5.

Remove the defective control from the fryer.

Figure 2-69

6.

Straighten the capillary tube on the new high limit, and thread

 

 

the capillary tube through the hole in the element hinge.

 

 

Figure 2-69.

 

7.

Reattach the capillary to the brackets on the upper and lower

 

 

parts of the elements.

 

 

DO NOT crimp or kink the capillary tube during installation.

 

 

Also, keep capillary tube behind element to protect from

 

 

damage from the basket or during cleaning. Damage to the

 

 

capillary tube reduces the life of the high limit, or causes the

 

 

high limit to fail.

 

8.

Connect wires to new high limit body and fasten to bracket,

 

 

using the two screws removed in the checkout part of this

 

 

section.

 

 

Make sure red reset button of high limit lines up with the

 

 

plunger that inserts into the element hinge.

 

 

To avoid electrical shock or other injury, run the capillary

 

 

line under and away from all electrical power wires and

 

 

terminals. The tube must never be in such a position

 

 

where it could accidentally touch the electrical power

 

 

terminals

 

9.

Re-install the rear cover and unit is now ready for use.

1003

 

2-25

Image 35
Contents Technical Manual Model OFE/OFG/OEA/OGA-341 FM06-030 Revised Table of Contents Injury SafetyIntroduction Which, if not avoided, could result in death or seriousInjuries and/or property damage could result TroubleshootingIf maintenance procedures are not followed correctly Problem Cause CorrectionCleaning the fryer Thoroughly TroubleshootingTroubleshooting Problem Cause Correction Display Cause Panel Board Correction Error CodesError Codes Display Cause Panel Board Correction Gas Units Maintenance HintsHigh Temperature Limit Control Remove the high limit from bracket Remove the two screws securing the high limit to the bracketPower terminals Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Position where it could accidentally touch the electricalComplete Control Panel ReplacementPower Switch Power Switch Excess force will damage probe Flame SENSOR/ Pilot / Ignitor Assembly GAS Temperature Probe Replacement ElectricFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Transformer ReplacementBoards Replacement To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Heating Elements Electric Blower Motor ReplacementWire Nos Voltage Wattage Ohms cold 30 31 34 35 36 Figure Checkout Power RemovedHeating ContactorsRe-apply power to unit and turn power switch to on Heating Contactors Electric Replacement Primary ContactorSpeaker Assembly 106 Limit Control Electric High TemperatureConnect the two electrical wires Terminals Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Terminals. The tube must never be in such a positionMotor Removal Autolift Transformer ReplacementFilter Pump and Motor Removal If applicable Actuator Motor ReplacementAutolift Actuator Motor Replacement Install new actuator in reverse order Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/O Drain switch wired N/O 707 Drain switch wired N/O Drain switch wired N/O Drain switch wired N/O Drain switch wired N/O 106 Genuine Parts When OrderingWarranty Parts Information IntroductionItem No Description Qty. per Well Gas Components Gas Burner Assembly Item No Description Qty. per Well Electric Components Item No Description Qty. per Well Item No Description Qty. per Well Model OFE/OFG/OEA/OGA-341 806 Item No Description Qty. per Unit √ recommended parts/*not shown √ recommended parts *not shown Item No Description Qty. per Well 2per well √ recommended parts/*not shown Item No Description Qty. per Well Item No Description Qty. per Well  recommended parts/*not shown OFG/OGA-341 OFG/OGA-342 Item No Description Qty. per Well Part Number Description OFG/OFE Electro Mechanical Parts ListItem No Description Qty ASSY. 341 Faucet Description Qty DIRECT-CONNECT Parts List Before March 1 Description QtyDIRECT-CONNECT Parts List Before March 1 ROD Extension Filter Valve PIN-COTTER Fitting Connector Male 1209

OEA/OGA-341, OEA/OGA-342, OFE/OFG-341, OFE/OFG-342 specifications

Henny Penny OFE/OFG-341, OEA/OGA-342, OFE/OFG-342, and OEA/OGA-341 are advanced cooking equipment designed primarily for the foodservice industry. These models are part of Henny Penny’s renowned line of pressure fryers, which are celebrated for their ability to deliver consistently high-quality, crispy fried foods while maintaining efficiency and safety.

One of the standout features of these models is their patented pressure frying technology, which allows food to be cooked at higher temperatures and pressures compared to traditional frying methods. This not only reduces cooking time significantly but also helps seal in moisture and flavor, resulting in juicy, tender products with a superior texture. The pressure frying system also uses less oil, making it a more economical choice for busy kitchens.

The OFE/OFG-341 and OFE/OFG-342 models are designed for versatility and ease of use. They offer programmable controls that allow operators to customize cooking times and temperatures for a range of food items, from chicken and fish to vegetables. This adaptability ensures that cooks can achieve the desired results each time, regardless of the menu item. The digital display is user-friendly, allowing staff to navigate through settings with ease.

Safety and maintenance are paramount in these designs. Each model is equipped with a robust safety locking system to prevent accidental opening during the cooking process. Additionally, they feature self-diagnostic capabilities that alert operators to potential issues before they become major problems, thereby reducing downtime.

In terms of construction, Henny Penny's OFE/OFG series is built with durable stainless steel, making them resistant to rust and easy to clean. They also come with an efficient filtration system that prolongs oil life, ensuring that food quality remains high while minimizing costs associated with oil replacement.

Moreover, the OEA/OGA models are designed with energy efficiency in mind. Equipped with advanced heating technology, these fryers conserve energy without compromising performance, making them an environmentally friendly choice.

With precise temperature controls, robust safety mechanisms, and a focus on efficiency, the Henny Penny OFE/OFG-341, OEA/OGA-342, OFE/OFG-342, and OEA/OGA-341 models set a high standard in commercial frying equipment, catering to the needs of modern kitchens while delivering delicious, consistent results.