Henny Penny OFE/OFG-341, OFE/OFG-342, OEA/OGA-342 Temperature Probe Replacement Electric

Page 17

Model OFE/OFG/OEA/OGA-341, 342

2-7. TEMPERATURE PROBE REPLACEMENT (ELECTRIC) (Continued)

Figure 2-18

2-8. FLAME SENSOR/ PILOT / IGNITOR ASSEMBLY (GAS)

4.Using a ½ inch wrench, remove the nut on the compression fitting. Figure 2-18.

5.Remove the probe from the frypot, and disconnect probe.

6.Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it extends one (1) inch (2.54cm) into the frypot.

7.Reconnect new probe onto wires, replace rear cover, and fryer is now ready for use.

The Henny Penny open fryer (gas) has electronic spark ignition that lights a standing pilot. The gap between the spark electrode and the pilot hood should be1/8 of an inch (3.18 mm). The flame sensor recognizes the pilot flame and allows gas to continue to the pilot. The flame sensor must send a minimum of two (2) micro amps to the ignition module. The pilot flame should be split in two by the flame sensor, causing the flame sensor to be bright red in color.

1.Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, BEFORE STARTING THIS PROCEDURE, MOVE THE MAIN POWER SWITCH TO THE OFF POSITION. DISCONNECT THE MAIN CIRCUIT BREAKERS AT THE CIRCUIT BREAKER BOX OR UNPLUG SERVICE CORD FROM WALL RECEPTACLE. TURN OFF THE MAIN GAS SUPPLY TO THE FRYER AND DISCONNECT AND CAP THE MAIN SUPPLY LINE TO FRYER, OR POSSIBLE EXPLOSION COULD RESULT.

1003

2-7

Image 17
Contents Technical Manual Model OFE/OFG/OEA/OGA-341 FM06-030 Revised Table of Contents Introduction SafetyWhich, if not avoided, could result in death or serious InjuryIf maintenance procedures are not followed correctly TroubleshootingProblem Cause Correction Injuries and/or property damage could resultCleaning the fryer Thoroughly TroubleshootingTroubleshooting Problem Cause Correction Display Cause Panel Board Correction Error CodesError Codes Display Cause Panel Board Correction Gas Units Maintenance HintsHigh Temperature Limit Control Remove the high limit from bracket Remove the two screws securing the high limit to the bracketWires and terminals. The tube must never be in such a Capillary line under and away from all electrical powerPosition where it could accidentally touch the electrical Power terminalsComplete Control Panel ReplacementPower Switch Power Switch Excess force will damage probe Flame SENSOR/ Pilot / Ignitor Assembly GAS Temperature Probe Replacement ElectricFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Transformer ReplacementBoards Replacement To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Heating Elements Electric Blower Motor ReplacementWire Nos Voltage Wattage Ohms cold Heating Checkout Power RemovedContactors 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Heating Contactors Electric Replacement Primary ContactorSpeaker Assembly 106 Limit Control Electric High TemperatureConnect the two electrical wires Where it could accidentally touch the electrical power Line under and away from all electrical power wiresTerminals. The tube must never be in such a position TerminalsMotor Removal Autolift Transformer ReplacementFilter Pump and Motor Removal If applicable Actuator Motor ReplacementAutolift Actuator Motor Replacement Install new actuator in reverse order Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/O Drain switch wired N/O 707 Drain switch wired N/O Drain switch wired N/O Drain switch wired N/O Drain switch wired N/O 106 Warranty When OrderingParts Information Introduction Genuine PartsItem No Description Qty. per Well Gas Components Gas Burner Assembly Item No Description Qty. per Well Electric Components Item No Description Qty. per Well Item No Description Qty. per Well Model OFE/OFG/OEA/OGA-341 806 Item No Description Qty. per Unit √ recommended parts/*not shown √ recommended parts *not shown Item No Description Qty. per Well 2per well √ recommended parts/*not shown Item No Description Qty. per Well Item No Description Qty. per Well  recommended parts/*not shown OFG/OGA-341 OFG/OGA-342 Item No Description Qty. per Well Part Number Description OFG/OFE Electro Mechanical Parts ListItem No Description Qty ASSY. 341 Faucet Description Qty DIRECT-CONNECT Parts List Before March 1 Description QtyDIRECT-CONNECT Parts List Before March 1 ROD Extension Filter Valve PIN-COTTER Fitting Connector Male 1209

OEA/OGA-341, OEA/OGA-342, OFE/OFG-341, OFE/OFG-342 specifications

Henny Penny OFE/OFG-341, OEA/OGA-342, OFE/OFG-342, and OEA/OGA-341 are advanced cooking equipment designed primarily for the foodservice industry. These models are part of Henny Penny’s renowned line of pressure fryers, which are celebrated for their ability to deliver consistently high-quality, crispy fried foods while maintaining efficiency and safety.

One of the standout features of these models is their patented pressure frying technology, which allows food to be cooked at higher temperatures and pressures compared to traditional frying methods. This not only reduces cooking time significantly but also helps seal in moisture and flavor, resulting in juicy, tender products with a superior texture. The pressure frying system also uses less oil, making it a more economical choice for busy kitchens.

The OFE/OFG-341 and OFE/OFG-342 models are designed for versatility and ease of use. They offer programmable controls that allow operators to customize cooking times and temperatures for a range of food items, from chicken and fish to vegetables. This adaptability ensures that cooks can achieve the desired results each time, regardless of the menu item. The digital display is user-friendly, allowing staff to navigate through settings with ease.

Safety and maintenance are paramount in these designs. Each model is equipped with a robust safety locking system to prevent accidental opening during the cooking process. Additionally, they feature self-diagnostic capabilities that alert operators to potential issues before they become major problems, thereby reducing downtime.

In terms of construction, Henny Penny's OFE/OFG series is built with durable stainless steel, making them resistant to rust and easy to clean. They also come with an efficient filtration system that prolongs oil life, ensuring that food quality remains high while minimizing costs associated with oil replacement.

Moreover, the OEA/OGA models are designed with energy efficiency in mind. Equipped with advanced heating technology, these fryers conserve energy without compromising performance, making them an environmentally friendly choice.

With precise temperature controls, robust safety mechanisms, and a focus on efficiency, the Henny Penny OFE/OFG-341, OEA/OGA-342, OFE/OFG-342, and OEA/OGA-341 models set a high standard in commercial frying equipment, catering to the needs of modern kitchens while delivering delicious, consistent results.