Henny Penny OFE-321 High Temperature, Checkout, Replacement, Drain the shortening from the frypot

Page 11
Manual background

Model OFE-321,322

2-12. HIGH TEMPERATURE

LIMIT CONTROL The electric units, models OFE-321/2/3/4, use the same high temperature control limits as the gas units, but the mounting of the capillary tube is different on the electric units compared to the gas units.

Checkout:

Use the same procedure as in the High Limit Temperature Control (Gas) Section.

Use replacement high limit, part no. 60241, 425 degree.

Replacement:

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other controls will have power.

1.Drain the shortening from the frypot.

2.Remove control panel.

3.Loosen small inside screw nut on capillary tube.

4.Remove capillary bulb from bulb holder inside the frypot.

5.Straighten the capillary tube.

6.Remove larger outside nut that threads into pot wall.

7.Remove the two screws that secure the high limit to the high limit bracket.

8.Remove the defective control from the control panel area.

2-11

409

Image 11
Contents SECTION 2. MAINTENANCE 2-3.COMPLETE CONTROL2.Remove control panel 2-6.I/O POWER SUPPLY 2-8.FILTER SWITCH 2-7.DRAIN MICROSWITCH ContinuedVoltage Replacement2-9.HEATING ELEMENTS CheckoutTemperature Spreader Probe 14. Replace the shortening in the frypot Mercury Contactor Checkout Power Removed2-10.HEATING CONTACTORS 3031 33 Continued Checkout Power Supplied2-10.HEATING CONTACTORS2-12.HIGH TEMPERATURE 2-11.SPEAKER ASSEMBLY1.Drain the shortening from the frypot 14.Replace front panel 15.Refill with shortening 2-12.HIGH TEMPERATURE LIMIT CONTROL Continued2-13 2-14