LIMIT CONTROL The electric units, models
Checkout:
Use the same procedure as in the High Limit Temperature Control (Gas) Section.
Use replacement high limit, part no. 60241, 425 degree.
Replacement:
To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other controls will have power.
1.Drain the shortening from the frypot.
2.Remove control panel.
3.Loosen small inside screw nut on capillary tube.
4.Remove capillary bulb from bulb holder inside the frypot.
5.Straighten the capillary tube.
6.Remove larger outside nut that threads into pot wall.
7.Remove the two screws that secure the high limit to the high limit bracket.
8.Remove the defective control from the control panel area.
409 |