Model
| Checkout (Power Supplied) |
CONTACTORS |
|
(Continued) |
|
To avoid electrical shock, make connections before applying power, take reading, and remove power before removing meter leads. The following checks are performed with the wall circuit breaker closed and the main power switch in the ON position.
1.
2.Using illustrations from previous page, check voltage as follows:
Test Points | Results |
From terminal 34 to 35 | The voltage should read |
From terminal 35 to 36 | the same at each terminal |
From terminal 34 to 36 |
|
Replacement:
If either contactor is defective it must be replaced as follows:
To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other controls will have power.
1.Remove only the wires directly connected to the contactor being replaced. Label the wires for replacement.
2.Loosen the screws securing the contactor bracket to the shroud.
3.Remove the contactor from the bracket.
4.Reinstall in reverse order.
405 |