Model
To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
2.Remove control panel.
3.Label and remove the wires from the switch. With test instrument, check across the terminals of the switch with the switch in the ON position, then in the OFF position. With the switch in the ON position, the circuit should be closed. With the switch in the OFF position, the circuit should be open. If the switch checks defective, replace by continuing with this procedure.
4.With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel.
5.Replace with new switch, and reconnect wires to switch.
6.Replace the control panel.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
2.Remove the control panel as discussed in Complete Control Panel Replacement Section.
3.Squeeze on the wire connector at the I/O board assembly to disconnect the wires from the transformer.
4.Using a Phillips head screwdriver, remove the two screws securing the transformer to the shroud.
5.Install the new transformer in reverse order.
405 |