Henny Penny OFE-321 manual DRAIN MICROSWITCH Continued, Filter Switch

Page 4
2-7. DRAIN MICROSWITCH (Continued)

Model OFE-321,322

2-7. DRAIN MICROSWITCH (Continued)

2.The following check should be made to determine if the drain microswitch is defective.

a.Remove the two screws securing the microswitch to the drain rod valve bracket.

b.Remove wires from the switch.

c.Check for continuity across the two outside terminals of the drain switch. If the circuit is open, the drain switch is defective. The circuit should only be opened by pressing on the actuator of the drain switch.

3.Replace switch in reverse order.

2-8. FILTER SWITCH

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Remove the control panel above the switch.

3.Label and remove the wires from the switch. With test instrument, check across the terminals of the switch with the switch in the ON position, and then in the OFF position. With the switch in the ON position, the circuit should be closed. With the switch in the OFF position, the circuit should be open. If the switch checks defective, replace it by continuing with this procedure.

4.With wires removed from the switch, push in on tabs on the switch and remove switch from the panel.

5.Push new switch into panel and reconnect wires.

405

2-4

Image 4
Contents 2-3.COMPLETE CONTROL SECTION 2. MAINTENANCE2.Remove control panel 2-6.I/O POWER SUPPLY 2-7.DRAIN MICROSWITCH Continued 2-8.FILTER SWITCHReplacement 2-9.HEATING ELEMENTSCheckout VoltageTemperature Spreader Probe 14. Replace the shortening in the frypot 2-10.HEATING CONTACTORS 3031 33 Checkout Power RemovedMercury Contactor Checkout Power Supplied 2-10.HEATINGCONTACTORS Continued2-11.SPEAKER ASSEMBLY 2-12.HIGH TEMPERATUREReplacement 2-12.HIGH TEMPERATURE LIMIT CONTROL Continued 14.Replace front panel 15.Refill with shortening2-13 2-14