Hoshizaki KM-1301SAH/3, KM-1301SRH/3 LED Lights and Audible Alarm Safeties, Sequence Step

Page 24

f) LED Lights and Audible Alarm Safeties

At startup, a 5-second delay occurs while the control board conducts an internal timer check. A beep occurs when the control switch is moved to the "ICE" position.

The red LED indicates proper control voltage and will remain on unless a control voltage problem occurs. The green LEDs 1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the control board is 1, 4, 3, 2. For details, see "II.B. Sequence of Operation."

 

Sequence Step

 

LED

 

Energized

 

 

 

Time LEDs are On

 

 

 

Components

 

 

Min.

 

Max.

 

Avg.

 

 

 

 

 

 

 

 

 

 

 

1-Minute Fill Cycle

4

 

WV

 

 

 

 

 

1 minute

Harvest Cycle

1, 4, 2

 

Comp, FMR, WV,

 

2 minutes

20 minutes

3 to 5 minutes

 

 

 

 

 

 

HGV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Harvest Pump Timer

1, 3, 2

 

Comp, FMR, PM,

 

0 seconds

50 seconds

harvest pump timer

 

 

 

 

 

 

HGV

 

 

 

 

 

setting

Freeze Cycle

1

 

Comp, FM/FMR,

 

5 minutes

freeze timer

30 to 35 minutes

 

 

 

 

 

 

PM, LLV

 

 

 

setting

 

 

Pump-Out Cycle

1, 4*, 3, 2

Comp, FMR, WV*,

 

10 seconds

20 seconds

*pump-out timer

 

 

 

 

 

 

PM, HGV

 

 

 

 

 

setting

The built-in safeties shut down the unit and have alarms as listed below.

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

 

 

 

1

High Evaporator Temp.

Check for harvest problem (stuck HGV or relay), hot

 

(temperature > 127°F)

water entering unit, stuck HM, or shorted thermistor.

 

(53°C)

 

 

 

 

2

Harvest Backup Timer

Check for open thermistor, HGV not opening, TXV or

 

(harvest > 20 min. for two cycles

LLV leaking by, low charge, or inefficient Comp.

 

in a row)

 

 

 

 

3

Freeze Timer

Check for F/S stuck closed (up), WV leaking by, HGV

 

(freeze > specified setting for

leaking by, PM not pumping, TXV not feeding properly,

 

two cycles in a row)

LLV not opening, low charge, HM not bypassing, or

 

Timer is factory set using S4 dip

inefficient Comp.

 

switch 9 & 10

 

 

 

 

To reset the above safeties, press the "ALARM RESET" button with the power supply on.

 

 

 

6

Low Voltage

Red LED will turn off if voltage protection operates.

 

(92Vac±5% or less)

The control voltage safeties automatically reset when

 

 

voltage is corrected.

7

High Voltage

 

 

(147Vac±5% or more)

 

 

 

 

Legend: Comp–compressor; FM–fan motor; FMR–fan motor-remote; F/S–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve; WV–inlet water valve

24

Image 24
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Icemaker KM-1301SAH air-cooledKM-1301SAH3 air-cooled KM-1301SWH water-cooled KM-1301SWH3 water-cooled KM-1301SRH remote air-cooled KM-1301SRH3 remote air-cooled Condenser Unit URC-14F Unit inches mmSpecifications II. General Information Construction KM-1301SAH, KM-1301SAH3 air-cooledKM-1301SWH, KM-1301SWH3 water-cooled KM-1301SRH, KM-1301SRH3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownMinute Fill Cycle Initial Harvest CycleS4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Pump-Out CycleHarvest Cycle ShutdownSequence Flow Chart Icemaker OffIce Level Lowered Control Board Control Board Layout Control BoardHarvest Backup Timer and Freeze Timer High Temperature SafetyLow Water Safety Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControls and Adjustments Default Dip Switch SettingsHarvest Timer S4 dip switch 1 Pump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Harvest Pump Timer S4 dip switch Factory Use S4 dip switchFreeze Timer S4 dip switch 9 S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch Refill Counter S5 dip switch 2 throughFloat Switch Control SwitchBin Control ThermistorTank Water Tank Valve Wiring Diagrams PressureSwitchAuxiliary Code T-0, U-0 KM-1301SAH air-cooledHigh Pressure Switch 1301SWH water-cooledAuxiliary Code T-0, U-0cKM Water KM-1301SRH3 remote air-cooled Auxiliary Code U-1 and Later a KM-1301SAH air-cooled KM-1301SWH water-cooled KM-1301SRH remote air-cooled KM-1301SAH3 air-cooled and KM-1301SWH3 water-cooled 1301SRH3 remote air-cooled Performance Data 1298 11592090 22201318 13231740 17601333 13001770 18401353 12222010 4791339 11972140 463IV. Service Diagnosis Diagnostic ProcedurePage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Shutdown Control Board Check Float Switch Check and Cleaning Float Switch CheckBin Control Check Float Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production BC Closed LED Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Instructions Preparing the Icemaker for Long StorageRemove the water from the icemaker water supply line Drain the water tank
Related manuals
Manual 101 pages 53.65 Kb

KM-1301SWH/3, KM-1301SRH/3, KM-1301SAH/3 specifications

The Hoshizaki KM-1301SRH/3, KM-1301SWH/3, and KM-1301SAH/3 are advanced ice makers designed for commercial use, addressing a wide variety of needs in restaurants, hotels, and bars. These models are known for their efficiency, durability, and innovative technologies that ensure the production of high-quality ice.

One of the standout features of these units is their ability to produce a high volume of ice, reaching up to 1,300 pounds per day, which is crucial for establishments with heavy ice demands. The machines utilize advanced cooling technology, allowing for faster ice production and minimizing the time required to refill ice bins. This makes them ideal for busy settings where speed and efficiency are paramount.

The KM-1301 series employs a unique stainless steel exterior that not only ensures longevity and resistance to corrosion but also enhances the aesthetic appeal of any commercial kitchen or bar. The interior is designed for easy cleaning, helping to maintain hygiene standards vital for food safety.

These ice makers utilize the proprietary Hoshizaki Cubelet Ice system, producing small, chewy ice cubes that are perfect for various beverages and food displays. The advanced design of the ice-making mechanism ensures that ice is formed quickly and efficiently, reducing energy consumption. Additionally, Hoshizaki’s CycleSaver technology optimizes the production process by reducing the amount of water used, making these machines environmentally friendly.

Another characteristic is their self-diagnostic capability, which allows for real-time monitoring of unit performance and quicker troubleshooting, minimizing downtime. The built-in alerts notify operators of any issues or maintenance needs, ensuring that the ice-making process remains uninterrupted.

The KM-1301 series also provides user-friendly controls that allow easy adjustments and monitoring of ice production settings. This flexibility enables businesses to meet varying ice demands based on seasonality or special events.

In summary, the Hoshizaki KM-1301SRH/3, KM-1301SWH/3, and KM-1301SAH/3 ice makers are exemplary choices for commercial ice production. With their high output, durable design, energy efficiency, innovative technologies, and user-friendly features, they cater effectively to the rigorous demands of the foodservice industry while maintaining a commitment to quality and sustainability.