Hoshizaki KM-260BAH, KM-201BAH, KM-260BWH, KM-201BWH LED Lights and Audible Alarm Safeties, Wv, Hgv

Page 20
5, 6, 4, 7
Pump-Out Cycle
Freeze Cycle
5, 7
10 seconds 20 seconds
factory default setting
5 minutes
25 to 30 minutes
freeze timer setting

seconds and the icemaker automatically stops. The control board will signal this problem using 7 beeps every 3 seconds.

The icemaker also automatically stops in cases of insufficient voltage (92Vac ± 5% or less). The control board will signal this problem using 6 beeps every 3 seconds.

When the proper supply voltage is resumed, the icemaker automatically starts running again.

f) LED Lights and Audible Alarm Safeties

The control board includes LED indicator lights, audible alarm safeties, and an output test feature. The “POWER OK” LED indicates control voltage and will remain on unless a control voltage problem occurs. The “POWER OK” LED flashes continuously when the bin is full and DV energizes for a maximum of 5 minutes to drain the water tank.

At startup, a 5 second delay occurs to stabilize the circuit. LEDs 4 through 8 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the board is 5, 6, 8, 9, 4, 7. For more information, see “2.

SEQUENCE OF OPERATION”.

Sequence Step

LED

Energized

 

Time LEDs are On

Components

Min.

Max.

Avg.

 

 

1 Minute Fill Cycle

8

WV

 

 

60 seconds

Harvest Cycle

5, 6, 8

WV, HGV,

2 minutes

20 minutes

3 to 5 minutes

Comp

Last 0, 10, 30, or 50 seconds (adjustable by dip switch) of harvest, WV de-energizes and PM energizes (LEDs 5, 6, and 7 are on)

Comp, PM,

FMS

Comp, HGV,

DV, PM

The built in safeties shut down the unit and have alarms as listed below.

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

 

High Evaporator Temp.

Check for harvest problem (stuck HGV or

1

(temperature > 127°F (53°C))

relay), hot water entering unit, stuck HM, or

 

 

shorted thermistor.

 

Harvest Backup Timer

Check for open thermistor, HGV not

2

(harvest > 20 min. for two

opening, TXV leaking by, low charge,

 

cycles in a row)

inefficient Comp, or WRV leaking by.

 

Freeze Timer

Check for a float switch stuck closed (up),

 

(freeze > specified setting for

WV leaking by, HGV leaking by, PM not

3

two cycles in a row)

pumping, TXV not feeding properly, low

 

Timer is factory set using S1

charge, or inefficient Comp.

 

dip switch 9 & 10

 

To reset the above safeties, press the “ALARM RESET” button with the power supply on.

15

Image 20
Contents Model KM-201BAH KM-260BAH KM-201BWH KM-260BWH Hoshizaki AMERICA, INC Contents Adjustment of Water Regulating Valve Page Specifications 1. Specifications a KM-201BAH KM-260BAH KM-201BWH KM-260BWH II. General Information 1. Construction KM-201BAH, KM-260BAHFront View KM-260BWH Icemaking Compartment Sequence of Operation ONE Minute Fill CycleInitial Harvest Cycle Freeze CycleNormal Harvest Cycle ShutdownDrain Control Board Control Board Layout $POUSPM#PBSEFeatures Maximum Water Supply Period 6 minutes Harvest Backup Timer and Freeze TimerHigh Temperature Safety Low Water SafetyLED Lights and Audible Alarm Safeties WV, HGVControls and Adjustments Default Dip Switch SettingsHarvest Timer S1 dip switch 1 Pump-Out Timer S1 dip switch 3Freeze Timer S1 dip switch 9 Pump-Out Frequency Control S1 dip switch 5Harvest Pump Timer S1 dip switch 7 Pump-Out Pump Motor Delay S2 dip switch Refill Counter S2 dip switch 3 Program Ver Control Board Check Procedure Overfreeze Detection Control S2 dip switch 5 Program VerAnti-Slush Control S2 dip switch 6 Program Ver Control Board Replacement ThermistorExplanation of Operation BIN Control Check ProcedureBIN Control Switches Control SwitchService Switch DrainCirculate WashHot Gas KM-201BWH, KM-260BWH Wiring Diagram Timing Chart KM-201BAHHV/FM OFF Relay Control Power Switch Freeze Cycle Harvest Cycle Performance Data Production PER 24 HR263 215 268 IV. Service Diagnosis Diagnostic Procedure Page No ICE Production Board Check Problem Possible Cause Remedy Evaporator is Frozen UP LOW ICE Production Other Service Information Removal and ReplacementService for Refrigerant Lines Refrigerant Recovery Evacuation and Recharge R-404ABrazing Compressor Drier HOT GAS Valve Hot Gas Valve Expansion Valve AIR-COOLED Condenser WATER-COOLED Condenser Caution FAN Motor AIR-COOLED Model Water Regulating Valve WATER-COOLED Model Caution Page Adjustment of Water Regulating Valve WATER-COOLED Model Pump Motor Water Valve Drain VALVE, Cleaning Valve Float Switch BIN Control Switch Thermistor Control BOX Power Switch Power RelayFuse Fuse HolderWater Tank Control Board TransformerCube Guide SeparatorPage Spray TUBE, Water Supply PIPE, Spray Guide Door Cleaning Procedure VI. Cleaning and Maintenance InstructionsCleaning Sanitizing Procedure Following Cleaning Procedure Storage BIN and Scoop MaintenanceExterior Panels Preparing the Icemaker for Long Storage AIR Filter AIR-COOLED ModelCondenser AIR-COOLED Model Remove the water from the potable water supply lineInlet Hose Washer Stop Valve

KM-201BWH, KM-260BWH, KM-201BAH, KM-260BAH specifications

The Hoshizaki KM-260BAH, KM-201BAH, KM-201BWH, and KM-260BWH are state-of-the-art ice machines designed for commercial use, demonstrating Hoshizaki's commitment to quality and innovation in the foodservice industry.

The KM-260BAH and KM-260BWH models are known for their impressive production capabilities, yielding up to 260 pounds of crescent ice daily. This ice type not only looks appealing but also has excellent cooling properties, making it a favorite in bars and restaurants. The KM-201BAH and KM-201BWH models produce up to 201 pounds of ice per day, making them ideal for establishments with moderate ice needs.

One of the standout features of these machines is the advanced air-cooled technology, which ensures optimal efficiency and reliability. The air-cooled condenser minimizes water usage, reducing operational costs while delivering consistent performance. Both BM-260 and KM-201 series models are equipped with a highly efficient refrigeration system, promoting rapid ice production even in warm environments.

The KM-260BAH and KM-260BWH models utilize a durable stainless steel exterior, providing not only a sleek appearance but also resistance to corrosion, ensuring longevity in demanding kitchen environments. The interior of these machines is designed with ease of cleaning in mind; a removable front panel allows quick access for maintenance, making service less time-consuming.

In terms of energy efficiency, these Hoshizaki ice machines meet Energy Star standards, offering reduced energy consumption and lower utility bills. The smart design also minimizes noise, creating a more pleasant atmosphere in bustling kitchens.

Another important characteristic of the KM-201BAH and KM-201BWH models is their flexible installation options, allowing users to adapt the machine to their space effortlessly. Additionally, the optional built-in storage bin can be paired seamlessly for enhanced convenience.

These ice machines also come with Hoshizaki's distinctive EverCheck alert system. This technology monitors the machine's operation, notifying operators of any necessary maintenance or issues before they become significant problems.

Overall, the Hoshizaki KM-260BAH, KM-201BAH, KM-201BWH, and KM-260BWH models showcase cutting-edge technology, energy efficiency, and user-friendly features, making them an excellent choice for any business in need of a reliable ice solution. Their focus on durability and performance positions them as a benchmark in the commercial ice machine sector, ensuring a consistent supply of high-quality ice.