4. ELECTRICAL CONNECTION

4. ELECTRICAL CONNECTION

WARNING

1.Electrical connection must be made in accordance with the instructions on a “WARNING” tag, provided with the pig tail leads in the Junction Box.

2.To prevent possible electrical shock to individuals or extensive damage to the equipment, install a proper ground wire to the ice dispensing bin that meets local code requirements.

A WHITE lead must be connected to the neutral conductor of the power source. Miswiring results in severe damage to the ice dispensing bin. See Fig. 2.

The ice dispensing bin must have a separate power supply or receptacle of proper capacity. See NAMEPLATE.

Check that the ice dispensing switch and the safety switch are operating correctly. See Fig. 3.

Ice Dispensing Switch

Push the button, and the unit should operate.

 

You can hear the operating sound.

Safety Switch

Continue pushing the button, and move the

 

spout toward you. Then the safety switch

 

should operate, and the unit will stop.

• An electrical permit and services of a licensed electrician may be required in some areas.

Ice Dispensing

Switch (Button)

 

Spout

 

Safety

 

Switch

Fig. 2

Ice

Station

Fig. 3

12

Image 12
Contents ISSUED Reliability is a beautiful thingTMJUNE 2001Page CONTENTS I. SPECIFICATIONS 1. NAMEPLATE RATING 2. DIMENSIONS/CONNECTIONS a with KM-280M or KM-500Mb with KM-630M Page II.INSTALLATION AND OPERATING INSTRUCTIONS 1. CHECKS BEFORE INSTALLATION2. LOCATION 3. SET UP - See Fig Page 4. ELECTRICAL CONNECTION 5. DRAIN CONNECTIONS - See Fig 6.FINAL CHECK LISTFig. 4 Drain Connection 7. START UP III. CLEANING AND MAINTENANCE INSTRUCTIONS 1. CLEANING INSTRUCTIONSaCLEANING PROCEDURE Inside of the Bin Agitator Spout of the Front Panel Chute2.MAINTENANCE HOSHIZAKI HOSHIZAKI AMERICA, INCPHONE 91A4JB10C