Extron electronic FOX 500 DA6 user manual Front Panel Indicators

Page 14

Installation and Operation, cont’d

1 6

6 feet

(1.8 m)

Part #70-335-01

Front Panel Indicators

CONFIG

RGB

LINK 1

AUDIO LINK 2 (OPTIONAL)

5

9

1

2

Tip

Ring

Sleeve (Gnd)

9-pin D

Connection

TRS Plug

 

 

 

Pin 2

Computer's RX line

Tip

Pin 3

Computer's TX line

Ring

Pin 5

Computer's signal ground

Sleeve

Figure 2-9 — Optional 9-pin TRS RS-232 cable

NThis port parallels the rear panel Remote RS-232 ports. If a front panel configuration connection is made, the rear panel Remote RS-232 port becomes inactive and the front panel Configuration port is active.

This port is RS-232 only, with the following protocols:

9600 baud

no parity

• 8 data bits

1 stop bit

no flow control

 

NThe maximum distances from the DA or receiver to the controlling device can vary up to 200' (61 m). Factors such as cable gauge, baud rates, environment, and output levels (from the unit and the controlling device) all affect transmission distance. Distances of about 50' (15 m) are typically not a problem. In some cases, the unit may be capable of serial communications via RS‑232 up to 250' (76 m) away.

 

Figure 2-10 — DA indicators

A

Power LED — This LED lights to indicate the power is

 

applied to the unit.

B Signal monitoring LEDs —

RGB LED — This LED lights on both units when the DA detects a sync signal on its video input:

• Horizontal sync (H) (for RGBHV video)

• Composite sync (S) (for RGBS video)

• Green (Sync on green) (G) (for RGsB or RsGsBs video)

Audio LED — This LED lights when the DA detects a low level audio signal for a short period of time. This LED goes dark if the audio signal drops below the minimum threshold for a short period of time.

Link 1 LED — This LED lights when the master receiver detects light on the fiber optic cable Optical 1 and the fiber optic cable Optical 2 is installed between the master receiver and DA output 1.

N Only one fiber optic cable, Optical 1, is required for video, audio, and serial command transmission. But, if you connect only one fiber optic cable, you do not receive RS-232 communications from the controlled device connected to the master receiver, and there is reduced RS-232 command and Windows control program functionality on the receiver. To receive responses

from the master receiver and for full functionality, you must install both fiber optic cables between the DA and the master receiver.

Link 2 LED — This LED lights when the DA detects light on the fiber optic cable Optical 2 connected to ouput 1.

2-10 FOX 500 DA6 • Installation and Operation

FOX 500 DA6 • Installation and Operation 2-11

Image 14
Contents FOX 500 DA6 Precautions Extron’s Warranty安全须知 中文 FCC Class a NoticeQuick Start Guide FOX 500 DA6 StepQuick Start Guide FOX 500 DA6 cont’d Chapter Two Installation and OperationFOX 500 DA6 Table of Contents Table of Contents, contd Appendix a Reference InformationAbout the FOX 500 DA6 IntroductionAbout this Manual Features Introduction, cont’dTwo FOX 500 DA6Mounting the Unit Installation and OperationTabletop placement Rack mountingInstallation and Operation, cont’d ConnectionsAlarm outputs port For remote monitoring Front panel Configuration port Rear panel serial ports connection Alarm outputs connectionFront Panel Indicators This port is RS-232 only, with the following protocolsInstallation and Operation, cont’d System Operation ThreeRear Panel Remote RS-232 Ports Remote ControlFront Panel Configuration Port Simple Instruction Set ControlUnit-initiated messages Remote Control, cont’dSymbols Front panel operationsUsing the command/response table Error responsesTimeout Command/response table for SIS commands Remote Memory presetsTotal pixels List sync frequencyAuto memory Front panel lock Executive modeAudio mute Auto imageResets Information requestsStarting the program Remote Control, cont’d Windows-based Program ControlInstalling the software Memory Preset area Mute area Status areaAdvanced Configuration area Video Adjustment areaOutput Configuration area Audio Output Level area Firmware upgradeAudio Adjustment area Open window AAppendix a Specifications Reference InformationGeneral Reference Information, cont’dAudio input Reference Information, cont’d Part Numbers Reference Information, cont’d

FOX 500 DA6 specifications

The Extron FOX 500 DA6 is a state-of-the-art digital distribution amplifier designed to deliver exceptional performance for professional audio and video applications. This unit is particularly well-suited for environments where high-quality signal distribution is crucial, such as corporate settings, educational institutions, and control rooms.

One of the key features of the FOX 500 DA6 is its ability to distribute HDMI and multi-format video signals over long distances without compromising quality. The device supports resolutions up to 4K at 60 Hz, ensuring that users can leverage the latest high-definition video formats. This capability is especially important for modern digital signage and AV integration, where visual clarity is paramount.

The FOX 500 DA6 employs cutting-edge HDCP compliance, which simplifies content sharing across various devices while maintaining security protocols. This feature ensures that protected content can be distributed seamlessly, a fundamental requirement in many professional settings.

Another significant aspect of the FOX 500 DA6 is its flexible input and output configuration. The device comes with six outputs, allowing for multiple display connections without the need for additional hardware. This versatility makes the HDMI distribution amplifier ideal for scenarios where multiple monitors or projectors are in use.

In terms of ease of use, the unit is equipped with an intuitive user interface that simplifies setup and operation. It also supports automatic switching between inputs, a valuable feature for users who require quick transitions between sources. Technicians will appreciate the unit's ability to maintain signal integrity, with features like signal amplification and equalization that compensate for signal loss over longer cable runs.

The FOX 500 DA6 is designed for reliability and durability, meeting the rigorous standards expected in commercial environments. Its compact form factor allows for easy integration into racks or other setups without taking up excessive space.

Lastly, the Extron FOX 500 DA6 supports various control options, including RS-232 and TCP/IP, enabling seamless integration into existing control systems. Whether managing a large-scale AV system or a simple setup, this device offers the performance and flexibility necessary to meet diverse user needs.

In summary, the Extron FOX 500 DA6 is a powerful digital distribution amplifier that caters to the demands of modern AV applications with its advanced features, reliable performance, and user-friendly design.