JXRB57 Kit
For Indoor Remote Blower Locations
Step3
Connect Ductwork
Downdraft
Duct Adapter
Outlet Cover
•The downdraft plenum can discharge from either the right or left side. Select the side that provides the best alignment to ductwork extending to the blower assembly below.
–For a left side discharge, install the outlet plate to the bottom of the plenum on the left side. Install the cover plate to the bottom of the right side. Reverse plates for a right side discharge.
.
•Connect the plenum to the ductwork. A transition is required to connect the
•Tape to seal all joints.
Step4
Connect Electrical
•Use electrical cable and connectors that conform to local codes (14 gauge min. is recommended). Use a length to reach between the vent and the blower/motor location.
•Attach the wire box removed from the blower conduit to the end of new wiring.
•Use wire nuts to secure the wire to the 3" remaining wires with plug.
•Insert the plug into the mating plug on the vent.
•Reinstall wire box with original screws.
•Install a junction box withing reach of the blower conduit.
•Use a conduit fitting to secure conduit to junction box. The red plastic
•Use wire nuts to connect wires.
Plenum
Provided
Mounting
Screws
Blower
Wire
Box
Connectors
Wire Nuts
Wiring to Blower Junction Box