GE Monogram ZGU365 installation instructions Mount Blower Finalize Installation

Page 20

JXBC57 Kit

For Outdoor Remote Blower Locations

Step5

Connect Electrical

Use electrical cable and connectors that conform to local codes (14 gauge min. is recommended). Use a length to reach between the vent and the blower/motor location.

Attach the wire box removed from the blower conduit to the end of new wiaring.

Use wire nuts to secure the wire to the 3" remaining wires with plug.

Insert the plug into the mating plug on the vent.

Reinstall wire box with original screws.

Plenum

Provided

Mounting

Screws

Blower

Wire

Box

3-Wire

Connectors

Wire Nuts

Wiring to Blower Junction Box

Step6

Mount

Blower

Step7

Finalize Installation

Mount the blower onto the mounting plate. Secure with original nuts.

Install damper to bottom of outlet with 4 screws.

Place the cover over the the assembled kit and secure with 16 screws.

20

Image 20
Contents GE Monogram Installation Instructions Downdraft Gas Cooktops Contents Design Information AccessoriesModels Available Advance Planning Tools Materials Required Cabinetry/DuctworkDuctwork Venting OptionsDuct Fittings Gas Downdraft CooktopElectrical supply Gas and Electrical SupplyGas supply Installation Install Downdraft VentRemove PackagingInstall the Ductwork Install Pressure RegulatorInstall the Cooktop Connect Power Assemble Burners Check IgnitionInstall Filters Check Operation Downdraft RAISE/LOWERJXRB57 Kit Prepare the VentDetermine Blower Location Connect Ductwork Connect ElectricalJXBC57 Kit Check Parts SuppliedMark Mounting Location Prepare the VentConnect Blower Wires Mount Blower Finalize Installation Page Page Page Monogram