Jackson Tempstar Series technical manual Volts Ratings Amps Circuit, Rinse Typical

Page 11

SECTION 1: SPECIFICATION INFORMATION

ELECTRICAL REQUIREMENTS

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is ade- quate and meets all applicable national and local codes. These numbers are provided in this manual simply for ref- erence and may change without notice at any given time.

TEMPSTAR/TEMPSTAR SDS:

 

 

TEMPSTAR LT/TEMPSTAR NB:

 

 

 

 

 

RINSE

 

TYPICAL

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL ELECTRICAL

 

 

 

HEATER

TOTAL ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

1

50

12KW@240V

71 A

90 AMP

208

1

50

N/A

28 A

35 AMP

208

1

50

14KW@240V

78 A

100 AMP

230

1

50

N/A

30 A

40 AMP

230

1

50

12KW@240V

78 A

100 AMP

 

 

 

 

 

 

230

1

50

14KW@240V

86 A

110 AMP

208

3

50

N/A

20 A

25 AMP

 

 

 

 

 

 

230

3

50

N/A

21 A

30 AMP

208

3

50

12KW@240V

45 A

60 AMP

380

3

50

N/A

10 A

15 AMP

208

3

50

14KW@240V

49 A

70 AMP

415

3

50

N/A

10 A

15 AMP

230

3

50

12KW@240V

48 A

60 AMP

440

3

50

N/A

8 A

15 AMP

230

3

50

14KW@240V

53 A

70 AMP

 

 

 

 

 

 

380

3

50

12KW@380V

29 A

40 AMP

208

1

60

N/A

26 A

35 AMP

380*

3

50

14KW@208V

34 A

45 AMP

230

1

60

N/A

28 A

35 AMP

415

3

50

12KW@415V

26 A

35 AMP

 

 

 

 

 

 

415

3

50

14KW@415V

29 A

40 AMP

208

3

60

N/A

18 A

25 AMP

440

3

50

12KW@460V

21 A

30 AMP

230

3

60

N/A

28 A

35 AMP

440

3

50

14KW@460V

25 A

35 AMP

460

3

60

N/A

8 A

15 AMP

208

1

60

12KW@240V

69 A

90 AMP

 

 

 

 

 

 

208

1

60

14KW@240V

76 A

100 AMP

TEMPSTAR S:

 

 

 

 

230

1

60

12KW@240V

76 A

100AMP

 

 

 

RINSE

 

TYPICAL

230

1

60

14KW@240V

84 A

110 AMP

 

 

 

HEATER

TOTAL ELECTRICAL

 

 

 

 

 

 

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

12KW@240V

43 A

60 AMP

208

1

60

N/A

6 A

15 AMP

208

3

60

14KW@240V

47 A

60 AMP

230

1

60

N/A

6 A

15 AMP

230

3

60

12KW@240V

46 A

60 AMP

 

 

 

 

 

 

230

3

60

14KW@240V

51 A

70 AMP

208

3

60

N/A

6 A

15 AMP

460

3

60

12KW@480V

22 A

30 AMP

230

3

60

N/A

6 A

15 AMP

460

3

60

14KW@480V

25 A

35 AMP

 

 

 

 

 

 

* This model is wired in a wye configuration for the heaters.

Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35

Issued: 12-07-2007 Revised: N/A

3

Image 11
Contents Steam Heated Models INSTALLATION/OPERATION Technical ManualPage ONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Tempstar NB Table of Contents VII VI.AVI.B VI.CSection Specification Information Steam Requirements Operating Cycle SecondsMinimum Other Cycle Times are Available Tank Capacity Tempstar LTRinse Typical This model is wired in a wye configuration for the heatersVolts Ratings Amps Circuit Tempstar SElectrical Connection Point Standard Clearance Between Dimensions TEMPSTAR/TEMPSTAR LT/NB Side Mounted Control BOXHeight Drain Floor Dimensions TEMPSTAR/NB/LT/S TOP Mounted Control BOXChemical Dispensing System Dimensions Tempstar SDSTable Dimensions Section INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsPower Block Operation Instructions Detergent Control False panel positioned in unit False Panel InstallationSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Common Problems Problem Dishes are not coming clean Problem Doors will not close completelyProblem Water leaks at the wash pump Problem Will not rinse during autocycleSection Parts Section Parts Section TOP Mounted Control BOX Assembly with Universal TimerParts Section TOP Mounted Control BOX Assembly Mechanical Timer Associated Hardware Other components not shownControl BOX Bottom Layout Side Mounted Control BOX AssemblyPower Switch SDS Side Mounted Control BOX Assembly Control Box Cover Weldment Hood Assembly Hood Assembly Bolted Single Support Design Cantilever ARM/DOOR Assemblies Cantilever Arm TUB Assembly Items for side-mounted control box not shown Steam TUB Assembly Connector, 1/2 90 Deg Frame Assembly Rinse Tank Assembly Coil Assembly Gate Valve, 3/4 NPT 04820-100-19-00 Incoming Steam Plumbing AssembliesWash Motors Model Volts Phase Wash Motor AssemblyOther parts not shown Motor & Pump AssemblyWash HEATERS/RINSE Heaters Model Volts PhaseTube Length Chart Item # Length Inches Tempstar Incoming PLUMBING/OUTLET Plumbing AssemblyWater Arrestor, 1/2 Tee, 3/4 x 3/4 x 1/2 Wprk KIT OptionTempstar LT & Tempstar NB Incoming Plumbing Assembly Tempstar SDS Incoming Plumbing Assembly Coil & Housing only Solenoid Valve & 3/4 NPT Vacuum Breaker Repair Parts KitsComplete Vacuum Breaker Assembly Complete 110 Volt Solenoid Valve Assembly1811 Wash & Rinse ARM/MANIFOLD AssembliesExploded View Tempstar SDS Dispenser Assembly CAM Holder Assembly Dispenser Plumbing Assembly Tempstar SDS Dispenser Assembly Feeder PumpMfg. No Lower Dispenser Assembly QTY DescriptionThermal Barrier Box Assembly Other Safety Door Interlock SDI components not shown False panel positioned in unit GO*BOX Components To Cold Water Supply Drain Quench AssemblyTo Dishmachine Drain Electrical Schematics For TOP Mount Units Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics for Side Mount Units Electrical Schematics Tempstar Side Mount 380 Volt 50 Hertz Three Phase Tempstar Side Mount 440-460 Volt 50/60 Hertz Three Phase Electrical Schematics Electrical Schematics Tempstar SDS 208-230 Volt 60 Hertz Single & Three Phase Tempstar SDS 380-440-460 Volt 50/60 Hertz Three Phase Tempstar SDS 380-415 Volt 50 Hertz Three Phase 5 Wire Tempstar SDS Dispenser Schematic Electrical Schematics For Options SDI Option Exhaust FAN HOOKUP/DRAIN Quench Options Section Jackson Maintenance Repair Centers Alabama to Florida Jackson Maintenance & Repair CentersFlorida to Maryland Service COMaryland to NEW York Jackson Service CompaNEW York to Pennsylvania Certified Service Center Rons ServiceCENTER, INC Rhode Island to WisconsinWisconsin to WYOMING/INTERNATIONAL

Tempstar Series specifications

The Jackson Tempstar Series is a line of high-performance heating and cooling systems designed to provide reliable temperature control for both residential and commercial applications. Known for their energy efficiency, advanced technology, and durable construction, the Tempstar Series offers a range of models to fit various needs and preferences.

One of the standout features of the Tempstar Series is its impressive SEER (Seasonal Energy Efficiency Ratio) and AFUE (Annual Fuel Utilization Efficiency) ratings, which indicate that these systems consume less energy compared to traditional heating and cooling units. This not only helps homeowners save on energy bills but also reduces their environmental footprint. The use of variable-speed technology in many models allows for more precise temperature control and quieter operation, contributing to overall comfort and efficiency.

The Tempstar Series incorporates advanced compressor technology, including the use of scroll compressors that provide smooth and efficient operation. This design reduces vibrations and noise, enhancing the overall user experience. In addition, the series is equipped with multi-stage heating and cooling capabilities, which ensure consistent temperature distribution throughout the space, making it ideal for areas with varying heating requirements.

Another key characteristic of the Jackson Tempstar Series is its built-in smart features, such as Wi-Fi connectivity and compatibility with smart thermostats. This allows users to monitor and control their HVAC systems remotely, providing convenience and flexibility. Some models even feature advanced diagnostic capabilities that alert homeowners to potential maintenance issues, helping to prolong the life of the unit and reduce repair costs.

The durability of the Tempstar Series is evident in its construction, with many units featuring high-quality materials designed to withstand the elements. This includes rugged cabinets and protective coatings that resist corrosion. Furthermore, Jackson offers comprehensive warranties on their products, providing peace of mind to customers.

In conclusion, the Jackson Tempstar Series represents a commitment to quality, efficiency, and innovation in heating and cooling technology. With its energy-efficient models, advanced features, and robust design, the series provides an excellent solution for those seeking reliable climate control. Whether for a residential or commercial application, the Tempstar Series stands out as a top choice for comfort and performance.