Jackson Tempstar Series INSTALLATION/OPERATION Instructions, Installation Instructions

Page 17

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

VISUAL INSPECTION: Before installing the unit, check the container and machine for damage. A damaged container is an indi- cator that there may be some damage to the machine. If there is damage to both the container and machine, do not throw away the container. The dishmachine has been inspected and packed at the factory and is expected to arrive to you in new, undamaged condition. However, rough handling by carriers or others may result in there being damage to the unit while in transit. If such a sit- uation occurs, do not return the unit to Jackson; instead, contact the carrier and ask them to send a representative to the site to inspect the damage to the unit and to complete an inspection report. You must contact the carrier within 48 hours of receiving the machine. Also, contact the dealer through which you purchased the unit.

UNPACKING THE DISHMACHINE: Once the machine has been removed from the container, ensure that there are no missing parts from the machine. This may not be obvious at first. If it is discovered that an item is missing, contact Jackson immediately to have the missing item shipped to you.

LEVEL THE DISHMACHINE: The dishmachine is designed to operate while being level. This is

 

 

important to prevent any damage to the machine during operation and to ensure the best results

 

 

when washing ware. The unit comes with adjustable bullet feet, which can be turned using a pair of

Raise

Lower

channel locks or by hand if the unit can be raised safely. Ensure that the unit is level from side to

 

 

 

side and from front to back before making any connections.

 

 

 

Frame with Adjustable Foot

PLUMBING THE DISHMACHINE: All plumbing connections must comply with all applicable local, state, and national plumbing codes. The plumber is responsible for ensuring that the incoming water line is thoroughly flushed prior to connecting it to any com- ponent of the dishmachine. It is necessary to remove all foreign debris from the water line that may potentially get trapped in the valves or cause an obstruction. Any valves that are fouled as a result of foreign matter left in the water line, and any expenses resulting from this fouling, are not the responsibility of the manufacturer.

CONNECTING THE DRAIN LINE: The drain for the Tempstar models covered in this manual are gravity discharge drains. All pip- ing from the 1 1/2” FNPT connection on the wash tank must be pitched (1/4” per foot) to the floor or sink drain. All piping from the machine to the drain must be a minimum 1 1/2” I.P.S. and shall not be reduced. There must also be an air gap between the machine drain line and the floor sink or drain. If a grease trap is required by code, it should have

a flow capacity of 5 gallons per minute.

WATER SUPPLY CONNECTION: Ensure that you have read the section entitled “PLUMBING THE DISHMACHINE” above before proceeding. Install the water supply line (3/4” pipe size minimum) to the dishmachine line strainer using copper pipe. It is recommended that a water shut-off valve be installed in the water line between the main supply and the machine to allow access for service.

The water supply line is to be capable of 20 ±5 PSI “flow” pressure at the recom- mended temperature indicated on the data plate.

In areas where the water pressure fluctuates or is greater than the recommended pres- sure, it is suggested that a water pressure regulator be installed. The Tempstar models

covered in this manual come with water pressure regulators as standard equipment. Incoming Plumbing Y-strainer Connection Please notify Jackson immediately if this component is not present on your machine.

Do not confuse static pressure with flow pressure. Static pressure is the line pressure in a “no flow” condition (all valves and ser- vices are closed). Flow pressure is the pressure in the fill line when the fill valve is opened during the cycle.

It is also recommended that a shock absorber (not supplied with the Tempstar model) be installed in the incoming water line. This prevents line hammer (hydraulic shock), induced by the solenoid valve as it operates, from causing damage to the equipment.

STEAM LINE CONNECTION: The steam machines come with lines by which the source steam needs to be connected. Connect all steam lines to the machine as all applicable codes provide. See machine data plate for information concerning steam flow pres- sure.

CHEMICAL DISPENSING EQUIPMENT: The Tempstar LT machine requires that a separate chemical feeder be connected to it to provide the required detergent and sanitizer. This feeder needs to be able to operate against a head of 25 PSI and provide 1.79 ml of a 10% Chlorine sanitizer per minute.

Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35

Issued: 12-07-2007 Revised: N/A

9

Image 17
Contents Steam Heated Models INSTALLATION/OPERATION Technical ManualPage ONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Tempstar NB Table of Contents VI.B VI.AVI.C VIISection Specification Information Minimum Other Cycle Times are Available Operating Cycle SecondsTank Capacity Tempstar LT Steam RequirementsVolts Ratings Amps Circuit This model is wired in a wye configuration for the heatersTempstar S Rinse TypicalElectrical Connection Point Standard Clearance Between Dimensions TEMPSTAR/TEMPSTAR LT/NB Side Mounted Control BOXHeight Drain Floor Dimensions TEMPSTAR/NB/LT/S TOP Mounted Control BOXChemical Dispensing System Dimensions Tempstar SDSTable Dimensions Section INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsPower Block Operation Instructions Detergent Control False panel positioned in unit False Panel InstallationSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Common Problems Problem Water leaks at the wash pump Problem Doors will not close completelyProblem Will not rinse during autocycle Problem Dishes are not coming cleanSection Parts Section Parts Section TOP Mounted Control BOX Assembly with Universal TimerParts Section TOP Mounted Control BOX Assembly Mechanical Timer Associated Hardware Other components not shownControl BOX Bottom Layout Side Mounted Control BOX AssemblyPower Switch SDS Side Mounted Control BOX Assembly Control Box Cover Weldment Hood Assembly Hood Assembly Bolted Single Support Design Cantilever ARM/DOOR Assemblies Cantilever Arm TUB Assembly Items for side-mounted control box not shown Steam TUB Assembly Connector, 1/2 90 Deg Frame Assembly Rinse Tank Assembly Coil Assembly Gate Valve, 3/4 NPT 04820-100-19-00 Incoming Steam Plumbing AssembliesWash Motors Model Volts Phase Wash Motor AssemblyOther parts not shown Motor & Pump AssemblyWash HEATERS/RINSE Heaters Model Volts PhaseTube Length Chart Item # Length Inches Tempstar Incoming PLUMBING/OUTLET Plumbing AssemblyWater Arrestor, 1/2 Tee, 3/4 x 3/4 x 1/2 Wprk KIT OptionTempstar LT & Tempstar NB Incoming Plumbing Assembly Tempstar SDS Incoming Plumbing Assembly Complete Vacuum Breaker Assembly Solenoid Valve & 3/4 NPT Vacuum Breaker Repair Parts KitsComplete 110 Volt Solenoid Valve Assembly Coil & Housing only1811 Wash & Rinse ARM/MANIFOLD AssembliesExploded View Tempstar SDS Dispenser Assembly CAM Holder Assembly Dispenser Plumbing Assembly Tempstar SDS Dispenser Assembly Feeder PumpMfg. No Lower Dispenser Assembly QTY DescriptionThermal Barrier Box Assembly Other Safety Door Interlock SDI components not shown False panel positioned in unit GO*BOX Components To Cold Water Supply Drain Quench AssemblyTo Dishmachine Drain Electrical Schematics For TOP Mount Units Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics for Side Mount Units Electrical Schematics Tempstar Side Mount 380 Volt 50 Hertz Three Phase Tempstar Side Mount 440-460 Volt 50/60 Hertz Three Phase Electrical Schematics Electrical Schematics Tempstar SDS 208-230 Volt 60 Hertz Single & Three Phase Tempstar SDS 380-440-460 Volt 50/60 Hertz Three Phase Tempstar SDS 380-415 Volt 50 Hertz Three Phase 5 Wire Tempstar SDS Dispenser Schematic Electrical Schematics For Options SDI Option Exhaust FAN HOOKUP/DRAIN Quench Options Section Jackson Maintenance Repair Centers Alabama to Florida Jackson Maintenance & Repair CentersFlorida to Maryland Service COMaryland to NEW York Jackson Service CompaNEW York to Pennsylvania Certified Service Center Rons ServiceCENTER, INC Rhode Island to WisconsinWisconsin to WYOMING/INTERNATIONAL

Tempstar Series specifications

The Jackson Tempstar Series is a line of high-performance heating and cooling systems designed to provide reliable temperature control for both residential and commercial applications. Known for their energy efficiency, advanced technology, and durable construction, the Tempstar Series offers a range of models to fit various needs and preferences.

One of the standout features of the Tempstar Series is its impressive SEER (Seasonal Energy Efficiency Ratio) and AFUE (Annual Fuel Utilization Efficiency) ratings, which indicate that these systems consume less energy compared to traditional heating and cooling units. This not only helps homeowners save on energy bills but also reduces their environmental footprint. The use of variable-speed technology in many models allows for more precise temperature control and quieter operation, contributing to overall comfort and efficiency.

The Tempstar Series incorporates advanced compressor technology, including the use of scroll compressors that provide smooth and efficient operation. This design reduces vibrations and noise, enhancing the overall user experience. In addition, the series is equipped with multi-stage heating and cooling capabilities, which ensure consistent temperature distribution throughout the space, making it ideal for areas with varying heating requirements.

Another key characteristic of the Jackson Tempstar Series is its built-in smart features, such as Wi-Fi connectivity and compatibility with smart thermostats. This allows users to monitor and control their HVAC systems remotely, providing convenience and flexibility. Some models even feature advanced diagnostic capabilities that alert homeowners to potential maintenance issues, helping to prolong the life of the unit and reduce repair costs.

The durability of the Tempstar Series is evident in its construction, with many units featuring high-quality materials designed to withstand the elements. This includes rugged cabinets and protective coatings that resist corrosion. Furthermore, Jackson offers comprehensive warranties on their products, providing peace of mind to customers.

In conclusion, the Jackson Tempstar Series represents a commitment to quality, efficiency, and innovation in heating and cooling technology. With its energy-efficient models, advanced features, and robust design, the series provides an excellent solution for those seeking reliable climate control. Whether for a residential or commercial application, the Tempstar Series stands out as a top choice for comfort and performance.