Jackson Tempstar Series technical manual Rinse Tank Assembly

Page 45

 

 

 

SECTION 5: PARTS SECTION

 

 

 

 

 

 

 

 

 

RINSE TANK ASSEMBLY

 

 

 

 

 

 

See page 27 to order phase

 

 

 

 

conversion kits for the heater.

 

2, 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

10

11

1

See page entitled

 

 

 

 

7, 8

 

 

 

 

9

12

“WASH HEATERS/RINSE

HEATERS”.

ITEM

QTY

DESCRIPTION

Mfg. No.

1

1

Booster Tank Weldment

05700-001-22-02

2

2

Locknut, 10-24 with Nylon Insert

05310-373-01-00

3

2

Washer, #10 S/S Flat

05311-173-01-00

4

1

Decal, Warning - Disconnect Power

09905-100-75-93

5

1

Booster Tank Cover Weldment

05700-001-29-30

6

6

Nut, Hex, 5/16"-18

05310-275-01-00

7

4

Locknut, 1/4"-20 with Nylon Insert

05310-374-01-00

8

4

Washer, 1/4" ID, S/S, Flat

05311-174-01-00

9

1

Thermostat, Rinse

05930-510-03-79

1Kit, Rinse Thermostat Replacement

 

 

(Includes: thermostat, brass fitting, 2 jumper wires & instructions)

06401-011-66-55

10

6

Washer, 5/16” I.D.

05311-175-01-00

11

1

Gasket, Rinse Heater

05330-200-02-70

12

1

Fitting, 1/4" Imperial Brass

05310-924-02-05

Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35

Issued: 12-07-2007 Revised: N/A

37

Image 45
Contents Steam Heated Models INSTALLATION/OPERATION Technical ManualPage ONE Year Limited Parts & Labor Warranty Manufacturers WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Tempstar NB Table of Contents VI.B VI.AVI.C VIISection Specification Information Minimum Other Cycle Times are Available Operating Cycle SecondsTank Capacity Tempstar LT Steam RequirementsVolts Ratings Amps Circuit This model is wired in a wye configuration for the heatersTempstar S Rinse TypicalElectrical Connection Point Standard Clearance Between Dimensions TEMPSTAR/TEMPSTAR LT/NB Side Mounted Control BOXHeight Drain Floor Dimensions TEMPSTAR/NB/LT/S TOP Mounted Control BOXChemical Dispensing System Dimensions Tempstar SDSTable Dimensions Section INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsPower Block Operation Instructions Detergent Control False panel positioned in unit False Panel InstallationSection Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting Section Common Problems Problem Water leaks at the wash pump Problem Doors will not close completelyProblem Will not rinse during autocycle Problem Dishes are not coming cleanSection Parts Section Parts Section TOP Mounted Control BOX Assembly with Universal TimerParts Section TOP Mounted Control BOX Assembly Mechanical Timer Associated Hardware Other components not shownControl BOX Bottom Layout Side Mounted Control BOX AssemblyPower Switch SDS Side Mounted Control BOX Assembly Control Box Cover Weldment Hood Assembly Hood Assembly Bolted Single Support Design Cantilever ARM/DOOR Assemblies Cantilever Arm TUB Assembly Items for side-mounted control box not shown Steam TUB Assembly Connector, 1/2 90 Deg Frame Assembly Rinse Tank Assembly Coil Assembly Gate Valve, 3/4 NPT 04820-100-19-00 Incoming Steam Plumbing AssembliesWash Motors Model Volts Phase Wash Motor AssemblyOther parts not shown Motor & Pump AssemblyWash HEATERS/RINSE Heaters Model Volts PhaseTube Length Chart Item # Length Inches Tempstar Incoming PLUMBING/OUTLET Plumbing AssemblyWater Arrestor, 1/2 Tee, 3/4 x 3/4 x 1/2 Wprk KIT OptionTempstar LT & Tempstar NB Incoming Plumbing Assembly Tempstar SDS Incoming Plumbing Assembly Complete Vacuum Breaker Assembly Solenoid Valve & 3/4 NPT Vacuum Breaker Repair Parts KitsComplete 110 Volt Solenoid Valve Assembly Coil & Housing only1811 Wash & Rinse ARM/MANIFOLD AssembliesExploded View Tempstar SDS Dispenser Assembly CAM Holder Assembly Dispenser Plumbing Assembly Tempstar SDS Dispenser Assembly Feeder PumpMfg. No Lower Dispenser Assembly QTY DescriptionThermal Barrier Box Assembly Other Safety Door Interlock SDI components not shown False panel positioned in unit GO*BOX Components Drain Quench Assembly To Dishmachine DrainTo Cold Water Supply Electrical Schematics For TOP Mount Units Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics Electrical Schematics for Side Mount Units Electrical Schematics Tempstar Side Mount 380 Volt 50 Hertz Three Phase Tempstar Side Mount 440-460 Volt 50/60 Hertz Three Phase Electrical Schematics Electrical Schematics Tempstar SDS 208-230 Volt 60 Hertz Single & Three Phase Tempstar SDS 380-440-460 Volt 50/60 Hertz Three Phase Tempstar SDS 380-415 Volt 50 Hertz Three Phase 5 Wire Tempstar SDS Dispenser Schematic Electrical Schematics For Options SDI Option Exhaust FAN HOOKUP/DRAIN Quench Options Section Jackson Maintenance Repair Centers Alabama to Florida Jackson Maintenance & Repair CentersFlorida to Maryland Service COMaryland to NEW York Jackson Service CompaNEW York to Pennsylvania Certified Service Center Rons ServiceCENTER, INC Rhode Island to WisconsinWisconsin to WYOMING/INTERNATIONAL

Tempstar Series specifications

The Jackson Tempstar Series is a line of high-performance heating and cooling systems designed to provide reliable temperature control for both residential and commercial applications. Known for their energy efficiency, advanced technology, and durable construction, the Tempstar Series offers a range of models to fit various needs and preferences.

One of the standout features of the Tempstar Series is its impressive SEER (Seasonal Energy Efficiency Ratio) and AFUE (Annual Fuel Utilization Efficiency) ratings, which indicate that these systems consume less energy compared to traditional heating and cooling units. This not only helps homeowners save on energy bills but also reduces their environmental footprint. The use of variable-speed technology in many models allows for more precise temperature control and quieter operation, contributing to overall comfort and efficiency.

The Tempstar Series incorporates advanced compressor technology, including the use of scroll compressors that provide smooth and efficient operation. This design reduces vibrations and noise, enhancing the overall user experience. In addition, the series is equipped with multi-stage heating and cooling capabilities, which ensure consistent temperature distribution throughout the space, making it ideal for areas with varying heating requirements.

Another key characteristic of the Jackson Tempstar Series is its built-in smart features, such as Wi-Fi connectivity and compatibility with smart thermostats. This allows users to monitor and control their HVAC systems remotely, providing convenience and flexibility. Some models even feature advanced diagnostic capabilities that alert homeowners to potential maintenance issues, helping to prolong the life of the unit and reduce repair costs.

The durability of the Tempstar Series is evident in its construction, with many units featuring high-quality materials designed to withstand the elements. This includes rugged cabinets and protective coatings that resist corrosion. Furthermore, Jackson offers comprehensive warranties on their products, providing peace of mind to customers.

In conclusion, the Jackson Tempstar Series represents a commitment to quality, efficiency, and innovation in heating and cooling technology. With its energy-efficient models, advanced features, and robust design, the series provides an excellent solution for those seeking reliable climate control. Whether for a residential or commercial application, the Tempstar Series stands out as a top choice for comfort and performance.