Jackson WASH/POWER Rinse Sections Combined, Electrical Requirements of the JFT-S

Page 12

SECTION 1: SPECIFICATION INFORMATION

ELECTRICAL REQUIREMENTS OF THE JFT-S

WASH/PREWASH PUMP MOTOR (2)

3 HP

POWER RINSE PUMP MOTOR (1)

2 HP

FINAL RINSE PUMP MOTOR (1)

1/2 HP

DRIVE MOTOR (1)

1/4 HP

EXHAUST FAN MOTOR (1)

0.31 KW

BLOWER DRYER MOTOR (1)

2.1 KW

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed- trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for reference and may change without notice at any given time.

CONTROLS, MOTORS, & BLOWER DRYER SECTION

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

N/A

22

30 AMP

230

3

60

N/A

22

30 AMP

460

3

60

N/A

11

15 AMP

600

3

60

N/A

10

15 AMP

CONTROLS, MOTORS, (NO BLOWER DRYER SECTION)

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

N/A

15

30 AMP

230

3

60

N/A

15

30 AMP

460

3

60

N/A

7

15 AMP

600

3

60

N/A

6

15 AMP

WASH/POWER RINSE SECTIONS (COMBINED)

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

N/A

16

20 AMP

230

3

60

N/A

16

20 AMP

460

3

60

N/A

8

15 AMP

600

3

60

N/A

7

15 AMP

JFT Series Technical Manual 7610-002-77-38

Issued: 03-16-2006 Revised: 09-14-2007

5

Image 12
Contents Technical Manual JFT JFT-SFor Jackson Model Manufacturers Warranty ONE Year Limited Parts & Labor WarrantyStop Pare Arret Revision Made Applicable Details Date ECN Model Serial No Installation Date Service Rep. Name Phone No Nomenclature for the Models Covered in this ManualTable of Contents VII Electrical Schematics Section Description Parts SectionSection Specification Information Specification Information CONTROLS, MOTORS, & Blower Dryer Section Electrical Requirements of the JFTFlowrate GPM Steam Booster Requirements WASH/POWER Rinse Sections Combined Electrical Requirements of the JFT-SJFT L-R & R-L Legend & Exhaust FAN Dimensions 1200 CFMJFT L-R Dimensions Open Door Cabinet Control 1943mmSpecification Information JFT R-L DimensionsJFT-S L-R & R-L Legend & Exhaust FAN Dimensions JFT-S L-R Dimensions 724mmJFT-S R-L Dimensions 914mm 1067mm 229mm 375mm 254mmSection INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Installing the JFT DishmachineDo not Tighten the Hardware AT this Point Individual Named SectionsLoad End Drain Connection Water Supply Connection Steam Trap Warranty 18 I.D. Square SQ InchesDeliming Operations Detergent Control Operating Instructions Cut-a-way detail showing direction of plates Section Preventative Maintenance Preventative Maintenance PRE-SCRAPPING/STRAINERSDAILY/WEEKLY/MONTHLY Maintenance DailyWeekly MonthlyMonthly /QUARTERLY/ANNUAL Maintenance QuarterlyAnnually Items not Requiring Maintenance Items that should not require maintenanceItems of note Section Troubleshooting Section Troubleshooting Section Common ProblemsProblem Machine fills, but fill is weak Problem Low wash tank/power rinse tank temperatureProblem Ware is coming out dirty Section Service Procedures Service Procedures Preparation StepsTools Required Time RequiredAfter Maintenance Actions Special Parts