SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS OF THE JFT-S
WASH/PREWASH PUMP MOTOR (2) | 3 HP |
POWER RINSE PUMP MOTOR (1) | 2 HP |
FINAL RINSE PUMP MOTOR (1) | 1/2 HP |
DRIVE MOTOR (1) | 1/4 HP |
EXHAUST FAN MOTOR (1) | 0.31 KW |
BLOWER DRYER MOTOR (1) | 2.1 KW |
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed- trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for reference and may change without notice at any given time.
CONTROLS, MOTORS, & BLOWER DRYER SECTION
|
|
| RINSE |
| TYPICAL |
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATINGS | AMPS | CIRCUIT |
208 | 3 | 60 | N/A | 22 | 30 AMP |
230 | 3 | 60 | N/A | 22 | 30 AMP |
460 | 3 | 60 | N/A | 11 | 15 AMP |
600 | 3 | 60 | N/A | 10 | 15 AMP |
CONTROLS, MOTORS, (NO BLOWER DRYER SECTION)
|
|
| RINSE |
| TYPICAL |
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATINGS | AMPS | CIRCUIT |
208 | 3 | 60 | N/A | 15 | 30 AMP |
230 | 3 | 60 | N/A | 15 | 30 AMP |
460 | 3 | 60 | N/A | 7 | 15 AMP |
600 | 3 | 60 | N/A | 6 | 15 AMP |
WASH/POWER RINSE SECTIONS (COMBINED)
|
|
| RINSE |
| TYPICAL |
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATINGS | AMPS | CIRCUIT |
208 | 3 | 60 | N/A | 16 | 20 AMP |
230 | 3 | 60 | N/A | 16 | 20 AMP |
460 | 3 | 60 | N/A | 8 | 15 AMP |
600 | 3 | 60 | N/A | 7 | 15 AMP |
JFT Series Technical Manual
Issued:
5