TROUBLESHOOTING CHART
The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified service company. Call
NOTE: To correctly and quickly diagnose the system, the chart below must be followed in sequential order.
| Problem |
| Probable Cause | Solution |
|
|
|
| |
| Main power light does not come on. | a.Fryer not plugged in. | a.Plug fryer into approved outlet. Must | |
|
|
|
| be properly grounded. |
|
| b.Breaker has tripped. | b.Reset the breaker lcoated on the | |
|
|
|
| bottom of the control panel |
|
| c. Main power switch is faulty. | c. Replace the main power switch. | |
|
|
|
| |
| Blower light does not come on. | a.Thermostat not turned on. | a.Set thermostat to desired | |
|
|
|
| temperature. |
|
| b.If blower comes on, blower light is | b.Replace blower light. | |
|
|
| faulty. |
|
|
| c. If Over Maximum Temperature light is | c. Reset | |
|
|
| on, | down below 425°F. Correct problem |
|
|
|
| which caused |
|
|
|
| (See page 10). |
|
| d.If unit has a filter, drain handle not | d.Secure drain handle in place | |
|
|
| locked into place. | behind the bracket. |
|
|
|
|
|
| Burner light does not come on. | • | Check for flame at each burner. If |
|
|
|
| no flame is present at either burner: |
|
|
| a.Spark module is faulty. | a.Replace spark module. | |
|
| • | Check for flame at each burner. If |
|
|
|
| flame is present at both burners: |
|
|
| b.Burner light is faulty. | b.Replace burner light. | |
|
|
|
|
|
| Burner light comes on, then goes | • | Check for spark at each burner. If |
|
| out (after 2 1/2 seconds). |
| no spark at either burner: |
|
|
| a.Spark electrode wires are not tight or | a.Tighten spark electrode wires or | |
|
|
| faulty. | replace. |
|
| b.Spark electrode is faulty or is out | b.See detail on page 26. | |
|
|
| of alignment. |
|
|
| • | Check for spark at each burner. If |
|
|
|
| spark occurs at both burners: |
|
|
| c. Gas is not hooked up properly or | c. Turn manual gas valve on. If using | |
|
|
| not turned on. | flexible connector with quick |
|
|
|
| disconnect, make sure that the quick |
|
|
|
| disconnect is completely engaged. |
|
| d.Spark electrode is faulty or is out | d.Align spark electrode. Replace spark | |
|
|
| of alignment. | electrode if faulty. Gap must be 1/8" |
|
|
|
| between electrode and pilot tube and |
|
|
|
| between pilot tube and burner (See |
|
|
|
| page 26). |
|
| e.Combination gas valve is faulty. | e.Replace combination gas valve after | |
|
|
|
| verifying it has voltage. |
|
|
|
|
|
|
|
|
|
|
12