Keating Of Chicago SERIES 2006 warranty Electrical Connection, GAS Leak Testing

Page 6

INSTALLATION

The installer is responsible for attaching the tipping restraint.

ELECTRICAL CONNECTION

The Keating IFM, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, the National Electrical Code, ANSI/NFPA No. 70. or the Canadian Electrical Code, CSAC-22.2 as applicable. A wiring diagram is located on the last page. In the U.S.A. and Canada, the electrical supply must be 120 VAC, 60 Hz.

The Keating Incredible Frying Machine (IFM) is equipped with a 9' neoprene covered, 3 wire electrical cord with a three-pronged grounded plug for protection against electrical shock. This plug must be placed into a 120V properly grounded three-pronged polarized outlet. For proper grounding procedures see local codes, or in the absence of local codes, the National Electrical Code ANSI/NFPA 70 (latest edition) or Canadian Electrical Code CAN 22.2 (latest edition) as applicable.

Before plugging in the fryer, confirm the outlet is properly polarized and grounded. If the hot and neutral terminals are reversed or the outlet is not properly grounded, the burners may not ignite (burner on light will go out after 2-1/2 seconds and the ignition processes will continue 3 times).

THIS APPLIANCE IS EQUIPPED

WITH A THREE-PRONG 120

VOLT NEMA 5-15 (GROUNDING)

PLUG FOR YOUR PROTECTION

AGAINST SHOCK HAZARD AND

SHOULD BE PLUGGED

DIRECTLY INTO A PROPERLY

GROUNDED AND POLARIZED

THREE-PRONG RECEPTACLE.

DO NOT CUT OR REMOVE THE

GROUNDING PRONG FROM

THIS PLUG.

IF DISCONNECTION OF THE RESTRAINT IS NECESSARY, IT MUST BE RECONNECTED WHEN THE FRYER IS RETURNED TO ITS ORIGINALLY INSTALLED POSITION.

GAS CONNECTION

PIPE JOINT COMPOUNDS RESISTANT TO PROPANE GASES MUST BE USED.

BEFORE OPERATING THIS FRYER, CHECK PIPE JOINTS FOR LEAKS BY USING A SOAP AND WATER SOLUTION ONLY. DO NOT USE AN OPEN FLAME!

Figure 2-3

Main Gas Connection

Connect the fryer to the main gas supply line at the rear of the fryer. The piping should be a minimum of 3/4" NPT supply pipe for a single fryer at the burner mani- fold. Batteries require larger supply lines. Installation must conform to the current local codes and National Fuel Gas Code (U.S.) ANSI Z223. 1/NFPA 54 (latest edition), Natural Gas Installation Code CAN/CGA-B149.1 or Propane Installation Code CAN/CGA-B149.2 (latest edition).

NOTE: If more than one gas fryer is on the same supply line, you may require a larger line. Consult your local gas company to assure adequate volume and pressure. Refer to serial plate for proper gas requirements for your particular model.

NOTE: Piping for a battery should be at least 1 1/4” to 1 1/2” IPS, depending on total BTU input. Consult your local gas supplier for appropriate battery piping size.

NOTE: The electrical wiring diagram for the fryer is located on the inside of the fryer door or in the back of this manual.

GAS LEAK TESTING

Prior to lighting your fryer:

1.Make sure all thermostats, switches and safety valves are in the “OFF” position.

2.Turn main On/Off manual gas valve to the “ON” position.

3.Have your plumber or gas company check for leaks with a soap solution. (NEVER check with an open flame!)

4

Image 6
Contents Contents Series 2006 Fryer ManualRead and Save this Manual for Future Reference Post this Label in a Prominent Location on Your Unit Introduction Clearances Damage During Shipment InstallationInstallation LevelingGAS Leak Testing Electrical ConnectionMaximum Incoming GAS Pressure OperatingGAS Pressure AT Manifold See FigureDigital Timer Resetting to Minutes Seconds Step CookingShut Down Canceling a Cycle Digital Timer ProgrammingPause Feature Cleaning and BOIL-OUTClose drain valve Preventive Maintenance MaintenanceWarranty Repairs Qualified Service PERGas Pressure ServiceService Diagnosis Air FlowCommon Problems Probable Cause Solutions Follow Sequentially SELF-HELP GuideTroubleshooting Chart Problem Probable Cause SolutionBreaker tripped Problem Probable Cause Solution Parts List Drain Valve Pull Rod AssemblyOrdering Parts Corresponds with parts list on Incredible Frying Machine GAS Fryer Rear Drain Model030862 Blower 053726 See pages 23-25 for Control Panel Parts List Incredible Frying Machine GAS Fryer Front Drain ModelThermostat Burner Assembly see Insulation High LimitDescription QTY Part Number IFM Control Panel Parts List with Timers Model IFM Control Panel Parts List Model 2006 CPU Located on Rear Drain Units only Description QTY Part Number 166 16 Burner Replacement KIT Description QTY Wiring Diagrams IFM 120V Connection Diagram no TIMERS, Front Drain Model Control Panel Insert Control Panel Back IFM Model 2006 Front Drain Without Lighted Rocker Switch IFM Model 2006 with Safe and Easy Filter IFM Model 2006 CPU Basket Lift Front Drain Page Page Page Page Effective 5/2006 Effective 5/2006 Warranty Service Information Keating Limited Warranty Card

SERIES 2006 specifications

The Keating of Chicago series, introduced in 2006, is a striking tribute to modern architecture and innovative design within urban environments. This furniture line, known for its sleek lines and functional form, reflects the spirit of Chicago’s rich architectural history while embracing contemporary aesthetics.

One of the key features of the Keating series is its modular design. This allows for versatility in residential and commercial spaces, enabling users to configure pieces in ways that suit their specific needs and preferences. The series includes a range of products, from sofas to coffee tables, all sharing a cohesive design language. The use of clean lines and geometric shapes promotes a sense of minimalism that appeals to modern sensibilities.

Technologically, the Keating series incorporates sustainable materials, reflecting a growing trend in furniture design focused on environmental responsibility. Many pieces are crafted from reclaimed wood, while upholstery options feature eco-friendly fabrics that are both durable and stylish. This commitment to sustainability is coupled with a focus on craftsmanship, ensuring that each piece is not only visually appealing but also built to last.

Another characteristic feature of the Keating series is its color palette and finishes. The collection often showcases neutral tones, allowing it to seamlessly integrate into various interior styles. Accents of rich colors or textures can be introduced through cushions or decorative elements, enabling individuals to personalize their spaces while retaining the series’ elegant aesthetic.

The Keating series also emphasizes comfort without compromising style. Seating options are designed with ergonomics in mind, featuring plush cushions and supportive frames. This thoughtful approach ensures that users can enjoy both the beauty and practicality of their furniture.

In summary, the Keating of Chicago series from 2006 represents a perfect fusion of modern design principles, functional versatility, and eco-consciousness. Its modular nature, sustainable materials, and commitment to comfort make it a sought-after choice for those looking to enhance their living or working environments with sophisticated furniture that stands the test of time.