Problem | Probable Cause |
| Solution |
|
|
| |
a. Actuator is faulty. | a. Replace actuator. | ||
does not move. |
|
|
|
|
|
| |
Basket(s) rise prematurely. | a. Electronic timer is faulty. | a. Replace timer. | |
| b. Basket lift relay is faulty. | b. Replace relay. | |
|
|
| |
Spark module flashing. | a. Steady OFF. | a. NO Power or Control Hardware | |
|
| Fault. | |
| b. Steady ON. | b. Power Applied; Control Okay. | |
| c. 1 Flash. | c. No flame sense (current trial | |
|
| only). Active until flame sense on | |
|
| next trial. | |
| d. 2 Flashes. | d. Marginal flame between 1.5mkA | |
|
| and 0.5mkA. | |
| e. 3 Flashes. | e. Ignition lockout; too many ignition | |
|
| failures: | |
|
| 1. Turn off unit. | |
|
| 2. | Check incoming gas. |
|
| 3. | Spark at electrode. |
|
| 4. | Electrode. |
| f. 4 Flashers. | f. Ignition lockout; too many flame | |
|
| losses: | |
|
| 1. Turn off unit. | |
|
| 2. | Check incoming gas. |
|
| 3. | Spark at electrode. |
|
| 4. | Electrode. |
| g. 5 Flashes. | g. Control hardware fault detected. | |
|
|
|
|