Operation

Reprogramming the charcoal filter timer

The active charcoal filter can only be used in recirculation mode and can not be used to exhaust fumes.

The charcoal filter timer is not not preset.

Before using the hood in recirculation mode, the charcoal filter timer must be programmed.

^Turn off the fan using the On/Off button.

^Press the Delayed Shut Down and Charcoal Filter buttons at the same time.

The indicator for the charcoal filter and one of the "–/+" indicators will flash.

The lit indicator shows the programmed time:

1st indicator from the left

= 120 hours

2nd indicator from the left

= 180 hours

3rd indicator from the left

= 240 hours

4th indicator from the left = deactivated

^Use the "–/+" button to select the desired time.

^Store the selection by pressing the charcoal filter button.

If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data.

17

Image 17
Contents Operating and Installation Instructions Ventilation System Page Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationGuide to the hood Delayed Shut Down On/Off button Fan power selectionChimney extension Recirculation vent Chimney Canopy Overhead lighting Active Charcoal FilterAir extraction Recirculation modeFunctional description Automatically switching back the Intensive power level Selecting the power levelIntensive setting OperationFan performance Turning off the fan Automatic Safety Shut Off Dimming the lighting Turning the lighting on/offChecking the filter timers Filter timersGrease filter Charcoal filtersReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Cleaning the casing Cleaning and CareStainless steel Stainless steel colored controlsRemoving the grease filter Grease filterRemoving the decor cover Inserting the decor cover Cleaning the grease filtersInserting the grease filter Active charcoal filters Cleaning and Care Changing the light bulbs MieleCare After Sales ServiceRepairs Installation Instructions Page Disposal of an old appliance Caring for the environmentDisposal of packing material Installation accessories Screw cover Reducing collarAllen wrench Plywood backing To install a plywood backingThis Appliance Must be Grounded Electrical dataAppliance dimensions Standard unit height H Distance between cooktop and hood SInstallation instructions InstallationProtective film DismantlingAir extraction Condensate trap Page Page Page Alteration rights reserved