Miele DA 5391 W, DA 5321 W, DA 5381 W Appliance dimensions, Standard unit height H

Page 27
Standard unit height (H):

Appliance dimensions

Cut out area in wall or ceiling for entrance of 6" (150 mm) ductwork or 5" (125 mm)

ductwork with a reducing collar.

The installation procedure differs depending on the model and venting method.

Before beginning the installation:

￿Read all instructions.

￿Determine height (S), regarding the user’s body height, i.e. a comfortable height for the user.

However, the greater the distance the less effectively cooking odors are drawn in.

￿If the hood is fitted flush to the ceiling, regard the possible unit height when selecting the installation height.

Standard unit height (H):

Air Extraction . . . . . . . . 29 5/16" - 41 9/16"

. . . . . . . . . . . . . . . . . . (745 - 1055 mm)

Recirculation. . . . . . . . 34 7/16" - 46 11/16"

. . . . . . . . . . . . . . . . . . (875 - 1185 mm)

To fit the lower chimney section, the distance between the top of the chimney and the ceiling must be at least 7/8" (20 mm).

27

Image 27
Contents Operating and Installation Instructions Ventilation System DA 5321 W DA 5381 W DA 5391 Wen - US, CA Contents Hazardous Or Explosive Materials And Vapors IMPORTANT SAFETY INSTRUCTIONSFor General Ventilating Use Only. Do Not Use To ExhaustTO REDUCE THE RISK OF A COOKTOP GREASE FIRE b NEVER PICK UP A FLAMING PAN - You may be burned EVACUATE AND CALL THE FIRE DEPARTMENTInstallation Functional description Air extractionRecirculation mode Guide to the Ventilation System Overhead lighting Light button On/Off button Fan power selectionChimney extension Chimney Canopy Charcoal filter Grease filter Recirculation vent Control panelSelecting the power level OperationTurning on the fan Fan performance Delayed Shut Down Turning off the fanAutomatic Safety Shut Off Dimming the lighting Turning the lighting On/OffCharcoal filter Filter timersChecking the filter timers Grease filtersReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Cleaning the casing Cleaning and CareCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulbs After Sales Service RepairsMieleCare Page Installation Instructions Page Caring for the environment Disposal of packing materialDisposal of an old appliance Vent hole 6 150 mm with reducing collar 5 125 mm Appliance dimensions3Air extraction vent installed upwards 1Air extraction mode 2Recirculation modeStandard unit height H Cooktops Distance between cooktop and hood SMiele Cooktops Non-MieleTo install a plywood backing Plywood backingInstallation Installation Dismantling Protective filmAir extraction Condensate trap Electrical connection THIS APPLIANCE MUST BE GROUNDEDGrounding Instructions Weight Technical dataPage Page Page M.-Nr.07 Alteration rights reserved