Miele DA 5321 W, DA 5391 W, DA 5381 W installation instructions Installation

Page 31
Installation

Installation

￿3 protective shields to prevent scratches to the chimney during installation.

￿1 vent collar

for use with 6" (150 mm) exhaust ducting

￿1 reducing collar for use with 5"

(125 mm) exhaust ducting.

￿Telescopic retaining plate secures the chimney extension

￿Installation kit for recirculation mode contains diverter, hose and hose clips (optional accessory)

￿CAUTION

To avoid risk of hand or other injury, avoid contact with sharp edges during the assembly and installation process.

8 large headed screws 5 x 40 mm

for securing the retaining plates and the canopy.

(S8 wall anchors included in the packaging are not for use in USA / CDN.)

2 M 6 locking nuts for securing the motor assembly.

2 screws 3.9 x 7.5 mm for securing the chimney.

1 lever for dismantling the chimney

Installation diagram

31

Image 31
Contents Ventilation System DA 5321 W DA 5381 W DA 5391 W Operating and Installation Instructionsen - US, CA Contents Hazardous Or Explosive Materials And Vapors IMPORTANT SAFETY INSTRUCTIONSFor General Ventilating Use Only. Do Not Use To ExhaustTO REDUCE THE RISK OF A COOKTOP GREASE FIRE b NEVER PICK UP A FLAMING PAN - You may be burned EVACUATE AND CALL THE FIRE DEPARTMENTInstallation Air extraction Functional descriptionRecirculation mode Guide to the Ventilation System Overhead lighting Light button On/Off button Fan power selectionChimney extension Chimney Canopy Charcoal filter Grease filter Recirculation vent Control panelOperation Selecting the power levelTurning on the fan Fan performance Turning off the fan Delayed Shut DownAutomatic Safety Shut Off Dimming the lighting Turning the lighting On/OffCharcoal filter Filter timersChecking the filter timers Grease filtersReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Cleaning the casing Cleaning and CareCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulbs Repairs After Sales ServiceMieleCare Page Installation Instructions Page Disposal of packing material Caring for the environmentDisposal of an old appliance Vent hole 6 150 mm with reducing collar 5 125 mm Appliance dimensions3Air extraction vent installed upwards 1Air extraction mode 2Recirculation modeStandard unit height H Cooktops Distance between cooktop and hood SMiele Cooktops Non-MieleTo install a plywood backing Plywood backingInstallation Installation Dismantling Protective filmAir extraction Condensate trap THIS APPLIANCE MUST BE GROUNDED Electrical connectionGrounding Instructions Weight Technical dataPage Page Page M.-Nr.07 Alteration rights reserved