EVACUATE AND CALL THE FIRE DEPARTMENT.

IMPORTANT SAFETY INSTRUCTIONS

￿WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*:

￿a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner.

BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,

EVACUATE AND CALL THE FIRE DEPARTMENT.

￿b) NEVER PICK UP A FLAMING PAN - You may be burned.

￿c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

￿d) Use a fire extinguisher ONLY if:

1)You have a class ABC extinguisher, and you know how to operate it.

2)The fire is small and contained in the area where it started.

3)The fire department is being called.

4)You can fight the fire with your back to an exit.

*Based on "Kitchen Firesafety Tips" published by NAFTA

￿Do not allow children to play with or operate the appliance or its controls. Supervise its use by the elderly or infirm.

￿Always turn on the hood when using the cooktop to prevent damage from condensation.

￿Never operate gas burners without cookware. Turn the burner off when not in use. Adjust the burner so that the flames do not extend beneath the cookware. Do not overheat the cookware, e.g. when using a wok. The hood can be damaged due to excessive heat from the burners and the cookware.

￿Do not use the hood without the grease filters in place.

￿Do not use a steam cleaner to clean the hood. Steam could penetrate electrical components and cause a short circuit.

5

Image 5
Contents en - US, CA Operating and Installation InstructionsVentilation System DA 5321 W DA 5381 W DA 5391 W Contents For General Ventilating Use IMPORTANT SAFETY INSTRUCTIONSOnly. Do Not Use To Exhaust Hazardous Or Explosive Materials And VaporsTO REDUCE THE RISK OF A COOKTOP GREASE FIRE b NEVER PICK UP A FLAMING PAN - You may be burned EVACUATE AND CALL THE FIRE DEPARTMENTInstallation Recirculation mode Functional descriptionAir extraction Guide to the Ventilation System Chimney extension Chimney Canopy Charcoal filter On/Off button Fan power selectionGrease filter Recirculation vent Control panel Overhead lighting Light buttonTurning on the fan Selecting the power levelOperation Fan performance Automatic Safety Shut Off Delayed Shut DownTurning off the fan Dimming the lighting Turning the lighting On/OffChecking the filter timers Filter timersGrease filters Charcoal filterReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Cleaning the casing Cleaning and CareCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulbs MieleCare After Sales ServiceRepairs Page Installation Instructions Page Disposal of an old appliance Caring for the environmentDisposal of packing material 3Air extraction vent installed upwards Appliance dimensions1Air extraction mode 2Recirculation mode Vent hole 6 150 mm with reducing collar 5 125 mmStandard unit height H Miele Cooktops Distance between cooktop and hood SNon-Miele CooktopsTo install a plywood backing Plywood backingInstallation Installation Dismantling Protective filmAir extraction Condensate trap Grounding Instructions Electrical connectionTHIS APPLIANCE MUST BE GROUNDED Weight Technical dataPage Page Page M.-Nr.07 Alteration rights reserved