Miele DA 5381 W, DA 5391 W, DA 5321 W Plywood backing, To install a plywood backing

Page 29
Plywood backing

Plywood backing

The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.

(If plywood backing is not needed, proceed to the included "Installation diagram".)

To install a plywood backing

￿Determine and mark the location of the retaining plate for the canopy as outlined on the "Installation diagram".

￿Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate.

￿Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder.

￿Mark a vertical cutting line along the center of each stud.

￿CAUTION

When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.

￿Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.

￿Proceed to the enclosed "Installation diagram" to complete the installation.

29

Image 29
Contents en - US, CA Operating and Installation InstructionsVentilation System DA 5321 W DA 5381 W DA 5391 W Contents For General Ventilating Use IMPORTANT SAFETY INSTRUCTIONSOnly. Do Not Use To Exhaust Hazardous Or Explosive Materials And VaporsTO REDUCE THE RISK OF A COOKTOP GREASE FIRE b NEVER PICK UP A FLAMING PAN - You may be burned EVACUATE AND CALL THE FIRE DEPARTMENTInstallation Recirculation mode Functional descriptionAir extraction Guide to the Ventilation System Chimney extension Chimney Canopy Charcoal filter On/Off button Fan power selectionGrease filter Recirculation vent Control panel Overhead lighting Light buttonTurning on the fan Selecting the power levelOperation Fan performance Automatic Safety Shut Off Delayed Shut DownTurning off the fan Dimming the lighting Turning the lighting On/OffChecking the filter timers Filter timersGrease filters Charcoal filterReprogramming the grease filter timer Reprogramming the timersReprogramming the charcoal filter timer Cleaning the casing Cleaning and CareCleaning the grease filter Grease filtersActive charcoal filter Changing the light bulbs MieleCare After Sales ServiceRepairs Page Installation Instructions Page Disposal of an old appliance Caring for the environmentDisposal of packing material 3Air extraction vent installed upwards Appliance dimensions1Air extraction mode 2Recirculation mode Vent hole 6 150 mm with reducing collar 5 125 mmStandard unit height H Miele Cooktops Distance between cooktop and hood SNon-Miele CooktopsTo install a plywood backing Plywood backingInstallation Installation Dismantling Protective filmAir extraction Condensate trap Grounding Instructions Electrical connectionTHIS APPLIANCE MUST BE GROUNDED Weight Technical dataPage Page Page M.-Nr.07 Alteration rights reserved