Appliance dimensions
1)
Exhaust connection C 7 7/8" (200 mm)
The exhaust connection is adjustable. This makes installation possible if the exhaust opening in the ceiling is not centered directly above the cooking surface. A maximum variance of 1 9/16" (40 mm) in each direction is possible.
Do not install this exhaust hood over cooktops burning solid fuel.
Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood:
-22" (550 mm) above electric cooktops,
-30" (762 mm) above gas cooktops,
-26" (650 mm) above an open electric grill or an open electric boiler/fryer.
If local building codes require a greater safety distance, follow their requirement.
If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance.
See "Important Safety Instructions" for further information.
CAUTION:
During the installation process, please be careful of sharp edges that can cause harm.
28