CVA615 Coffee System
Technical Information
4.15Brew Unit Drives
Refer to Figure
When the brew unit is placed in the appliance, it locks into position. The locking mechanism switch lug (Item 3) activates the brew unit present switch (Item 4). The drive shaft (Item 6) engages with the drive shaft socket.
1Brew Unit Drive Shaft Socket
2Socket
3Locking Mechanism Switch Lug
4Switch – Brew Unit Present Switch
5Nozzle – Coffee Heater
6Drive Shaft
Figure
37