CVA615 Coffee System
Technical Information
5.19Checking Temperature at Coffee Dispenser
Warning!
To avoid adverse operating conditions:
Do not deviate from the procedure.
Do not change any other settings or values during this procedure.
1.Set the grinding grade to medium.
2.Set the coffee quantity to medium.
3.Set the Medium Coffee temperature to medium (standard setting).
4.Turn off the appliance.
5.Press and hold the Small Coffee Button, Large Coffee Button and the Hot Water Button. Turn the Selector Switch to the “On with Light” position.
The following is displayed:
LANGUAGE
RINSING
6.Press the Medium Coffee Button 12 times. The following is displayed:
DIAGNOSIS
LANGUAGE
7.Press the Small Coffee Button 1 time.
8.Press the Medium Coffee Button 2 times.
The following is displayed: | Note: |
| This value may vary |
1 COFFEE
N0IMPULS.350
9.Observe the numeric value in the lower right corner of the display.
If a value of “350” is displayed; proceed to step 14.
If the value is not 350; proceed to step 10.
10.Press the Small Coffee Button 1 time. A blinking box will appear at the end of the numeric value.
63