CVA615 Coffee System
Technical Information
5.44Water Path Leakage Test
In the event water is present in bottom of the appliance, or a leak is suspected; the following procedure will help in locating the source of the leak.
Caution!
Heaters can be hot during this test and hot water may escape from the system.
1.Fill the Water reservoir completely
2.Place the appliance into the Service Mode with the Selector Knob in the Programming position. Refer to Section 6 - Fault Diagnosis for further information on service mode access.
3.Press and hold all three coffee buttons - check for signs of leakage (dripping, squirting etc...)
4.Release the three coffee buttons to end the test
If steps
5.Fill the Water reservoir completely
6.Place the appliance into the Service Mode
7.Quickly turn the selector knob to the “Operation” position
8.Press and hold all three coffee buttons for 30 seconds
9.Quickly turn the selector knob to the “Programming” position
10.Press and hold all three coffee buttons - check for signs of leakage (dripping, squirting etc...)
11.Release the three coffee buttons to end the test
96