GENERAL

INTRODUCTION

This manual is prepared for the use of trained service technicians and should only be used by those who are properly qualified. This manual is not intended to be all encompassing. You should read, in it's entirety, the repair procedure you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should not be attempted.

Disconnect the electrical power and follow lockout / tagout procedures

Certain procedures in this manual require electrical test or measurements while power is applied to the machine. Exercise extreme caution at all times when attempting these procedures. Before testing, disconnect electrical power and follow lock/out tagout procedures, then attach test equipment and reapply power to test.

Procedures in this manual will apply to all RRG models unless specified. No procedure in this manual will require the removal or raising of the griddle plate. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific.

INSTALLATION

Generally, installations are made by the dealer or contracted by the dealer or owner. Detailed installation instructions are included in the Installation and Operation Manual that is sent with each unit. However, it should be noted that an improperly installed unit, especially an unlevel unit can lead to premature electrical component failures. A unit that is higher in the front will cause the flue gases to vent improperly and gather in the front near the electrical components. All RRG models must be installed with an externally mounted regulator.

OPERATION

Detailed operation instructions are included in the Installation & Operation Manual sent with each unit and are also available at WWW.VULCANHART.COM .

CLEANING

Detailed cleaning procedures are included in the Installation & Operation manual sent with each unit.

LUBRICATION

No lubrication is required on this equipment.

SPECIFICATIONS

All RRG models operate on 120 volt, 60 hertz, single phase at 1.0 amps. All models are equipped with electric solid state thermostats, automatic spark igniters and pilot safety circuit. All models are equipped with 27,500 BTU/HR burners as standard equipment. One burner is used for every 12 inches of griddle surface. Natural gas models are to operate at 5.0" W.C. manifold pressure and LP models at 10.0" W.C. manifold pressure with all burners on.

- 4 -

Image 4
Contents Heavy Duty Gas Griddles 48RRGTable of Contents Regulator TROUBLESHOOTING………………………………… Burner TROUBLESHOOTING………………………………………GAS Pressure MEASUREMENT…………………………………...17 Installation Operation Cleaning Lubrication SpecificationsGeneral Introduction36RRG Configuration Shown Component LocationExterior Panels Wiring Configuration Thermostat TroubleshootingSymptom Burner will not Come on ThermostatTemperature Probe Temperature Probe RemovalTemperature Probe Installation Thermostat RemovalAdjustments CalibrationPower ON/OFF Switch Power Switch TroubleshootingSymptom no Power Being Supplied to the Unit Power Switch RemovalIndicator Light Safety Ignition ModuleIndicator Light Troubleshooting Indicator Light RemovalSafety Ignition Module Troubleshooting Symptom no Spark Between Pilot Head and ElectrodeSymptom Electrode Continually Sparks After Pilot is LIT Solenoid ValvesSolenoid Valve Troubleshooting Symptom no GAS Flow to BurnerInput GAS Line Back Center Retaining Screw Output GAS Lines Double Solenoid ValveBrass Pilot Valve Pilot Troubleshooting Symptom Pilot will not LightPilot Assembly Removal PilotBurner Burner TroubleshootingBurner Removal Burner Adjustment GAS Regulator GAS Pressure MeasurmentSequence of Operation Pressure TAP AT #1 BurnerWiring Diagrams Wiring Diagram 36-INCH Griddle Wiring Diagram 48-INCH Griddle Wiring Diagram 60-INCH Griddle