Vulcan-Hart GDC60 ML-52584 Before First USE, Lighting Pilots on Griddles with Electric Ignition

Page 8

BEFORE FIRST USE

The griddle plate is shipped with a protective coating. Remove this coating before cooking with griddle. Clean the griddle with a damp cloth and mild detergent. Rinse with a clean damp cloth and wipe dry.

The griddle must be seasoned prior to first use. See the section titled SEASON GRIDDLE SURFACE for seasoning procedure.

LIGHTING PILOTS ON GRIDDLES WITH ELECTRIC IGNITION

CAUTION: Do not turn the electric supply on without making sure the gas is flowing to the pilots. Failure to do this may shorten igniter life.

1.Turn all burner valves OFF. Wait 5 minutes to allow any gas to escape.

2.Turn the gas supply ON.

3.Turn the main electric switch ON. The red light comes on.

4.Pilots should light as soon as the gas supply reaches the pilot. Verify this before proceeding to normal operation.

If pilot goes out, the electric igniter will relight the pilot.

If electricity to the griddle goes off, gas supply to the pilots and to the burners is automatically shut off.

NORMAL OPERATION

A red thermostat on the front control panel regulates the temperature of each platen and has a separate on-off switch.

Twin radial cams adjust height of the platen above the griddle for optimal cooking performance. Gradations from 5/32" to 1" in 32nds are available with markings from 3/16" to 16/16" or 1".

A black thermostat on the front control panel regulates the temperature of each foot-wide section of griddle surface.

1.Follow procedure for lighting pilots before proceeding.

2.Adjust radial cams on platens for height of platen.

3.Turn switch ON and set thermostat to desired temperature. Amber light flashes on when heating, off when thermostat is satisfied.

4.Repeat step 3 for all sections of the griddle and all platens.

— 8 —

Image 8
Contents Installation Important for Your Safety For Your SafetyLocation InstallationUnpacking Installation Codes and Standards AssemblyGAS Connections Testing the GAS Supply Piping SystemStand Fig Electrical Connections Electrical DataOperation Normal Operation Before First USELighting Pilots on Griddles with Electric Ignition Cleaning the Griddle Preheat GriddleSeason Griddle Surface AT the END of the DAYCare and Cleaning of the Platen After Each UseDuring The Day Once a DayReplacement of the Platen Surface MaintenanceCare of the Stainless Steel Housing Page Service and Parts Information Troubleshooting Problem Possible CauseProblem Possible Cause Form 30501 Rev. a