Vulcan-Hart VL3GSS ML-52393, VL2GSS ML-52389 Plumbing Connections, Water Requirements

Page 6

PLUMBING CONNECTIONS

WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES.

Water Requirements

Proper water quality can improve the taste of the food prepared in the steamer, reduce liming in the steam generator and extend equipment life. Local water contitions vary from one location to another. Ask your municipal water supplier for details about your local water supply prior to installation.

WATER REQUIREMENTS

Supply Pressure

20 — 60 psig

Hardness*

less than 3 grains

Silica

less than 13 ppm

Total Chlorine

less than 4.0 ppm

pH range

7 — 8

Undissolved Solids

less than 5 microns

*17.1 ppm = 1 grain of hardness

Presence of sediment, silica, excess chlorides or other dissolved solids may lead to a recommendation for alternate form(s) of water treatment. Test the water with the test strip included with the steamer. Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. A local water treatment specialist should be consulted before installation of steam generating equipment.

Water Supply Connections

A water filter system is recommended for the water supply line going to the treated water inlet of your steamer. Follow the recommendations for use and installation instructions shipped with the water filter.

If a water filter is not installed, the steamer or steam generator warranty may be limited.

Filtered Water Connection — 1/4" NPT. Used for boiler feed water.

Unfiltered Water Connection — 1/4" NPT. Used as cold water condenser on boiler blow-down line.

Drain

CAUTION: In order to avoid any back pressure in the steamers, do not connect solidly to any drain connection.

The drain must be the open air gap type. Provide a suitable floor sink with a minimum depth of 12" (30 cm). The floor sink is NOT to be located directly under the steamer. Local codes require that the maximum temperature of drain water must be no greater than 140°F (60°C). Refer to Fig. 4 on page 9. The drain pipe should be either iron or copper. DO NOT use PVC pipe; PVC pipe may lose its rigidity or glue may fail.

– 6 –

Image 6
Contents Installation Important for Your Safety For Your SafetyTable of Contents Installation VL2 & VL3 GAS Food SteamersGeneral Installation Codes and Standards Requirements for GAS AppliancesLeveling and Anchoring Plumbing Connections Water RequirementsFLUE-GAS Exhaust a Ventilating Hood is Recommended Testing the GAS Supply SystemGAS Connection Electrical ConnectionInstallation Drawing Models VL2GSS & VL3GSSDrain Requirements Operation Steamers with Electronic IgnitionPage Steam Cooking Compartment Operation Shut Down AT END of DAYTo Shut OFF for AN Extended Shutdown Selection of Pans for Steam Cooking Fresh ProductCleaning Cooking Compartment Drains Boiler BlowdownCompartments Maintenance Door GasketsWater Treatment System Troubleshooting

VL2GSS ML-52389, VL3GSS ML-52393 specifications

Vulcan-Hart, a leader in commercial kitchen equipment, offers a range of high-performing appliances, among which the Vulcan-Hart VL3GSS ML-52393 and VL2GSS ML-52389 stand out. These models are designed with the needs of restaurants and food service operations in mind, providing efficient and durable solutions for various cooking applications.

The Vulcan-Hart VL3GSS ML-52393 is a three-burner, gas-fired range designed with a stainless steel exterior that not only enhances durability but also simplifies cleaning. Its powerful burners deliver precise heat control, enabling chefs to cook a diverse array of dishes, from delicate sauces to hearty stews. This model features a combination of open burners that provide excellent temperature regulation, ensuring that food is cooked evenly without hot spots. The range also includes a standard oven, providing ample space for baking and roasting, making it a versatile choice for any kitchen.

On the other hand, the Vulcan-Hart VL2GSS ML-52389 is a two-burner range that caters to smaller kitchens or lower-volume operations. Despite its compact size, it offers the same high-quality construction and efficient performance as its larger counterpart. The VL2GSS model also showcases open burners that allow for quick adjustments to heat levels, which is essential for busy kitchen environments where time is of the essence. Its stainless steel front and sides ensure durability, reliability, and a professional appearance.

Both models showcase advanced technologies that enhance their functionality. They are equipped with standing pilots for immediate ignition and safety, ensuring that the kitchen can operate seamlessly, even during peak hours. Additionally, they incorporate easy-access controls that simplify operation and maintenance, allowing staff to focus on delivering exceptional food quality.

In terms of energy efficiency, both the VL3GSS and VL2GSS are designed to minimize gas consumption while maximizing performance. This not only translates into cost savings for operators but also supports sustainable practices in the kitchen.

In summary, the Vulcan-Hart VL3GSS ML-52393 and VL2GSS ML-52389 are engineered to meet the rigorous demands of the food service industry. With their durable construction, precise heat control, and energy-efficient technologies, these gas ranges are perfect for chefs looking to enhance their cooking capabilities while maintaining high standards of performance. Whether for high-volume cooking or more specialized tasks, both models exemplify Vulcan-Hart's commitment to quality and innovation in commercial kitchen equipment.