VHX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
REMOVAL AND REPLACEMENT OF PARTS
PRESSURE SWITCH CONTROL
BOX COMPONENTS
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
CAUTION: Certain components in this system are subject to damage by electrostatic discharge during field repairs. A field service grounding kit is available to prevent damage. The field service grounding kit must be used anytime a control board is handled.
1.Open the cabinet base door.
2.Remove cover from pressure switch control box.
3.Disconnect lead wires from component being replaced.
4.To remove:
A. Cycling pressure switch.
1)Disconnect compression fittings in the pressure supply line leading to the switch.
2)Remove mounting nuts from pressure switch mounting panel.
3)Disconnect conduit from box.
Page 7 of 48 |
| F25154 (February 2004) |
|