Pentair PLDE36, PLDE48 owner manual Module Cleaning PRO- Cedure, Special Cleaning Instructions

Page 8

MODULE CLEANING PRO- CEDURE

Risk of chemical burns. Do not attempt to acid clean the filter or module. If the filter re-

quires acid cleaning, have a trained pool professional do the job.

Follow all steps in the “Disassembly” section of this manual.

The filter module should be removed and cleaned when pressure rises more than 10 psi (69 kPa) above startup

When to Clean the Filter

The filter module should normally be cleaned when the pressure gauge reading increases 10 PSI over the start-up pressure (record the start-up pressure under “Owner’s Information”, Page 3).

In some pools, accessories such as fountains or pool cleaners may be noticeably affected by the normal decrease in flow as the filter becomes dirty. If so, clean the filter more frequently (that is, at a pressure increase of less than 10 PSI) in order to maintain the re- quired flow.

pressure. See also “When to Clean the Filter,” below.

NOTICE: Do not expose the filter module to sunlight for any extended period of time.

NOTICE: When sanitizing your pool using PHMB (poly- hexamethylene biquanide based) cleaners, use only PHMB cleaners to clean the module. When using PHMB sanitizers, the filter module MUST be cleaned more thor- oughly and frequently than for a pool using chlorine. Follow manufacturer’s instructions carefully. Use of any other type of cleansers with PHMB pool sanitizers will void the filter’s warranty.

NOTICE: Avoid washing filter debris into the outlet port. Remove drain plug and flush foreign material from inside of tank before removing filter module.

1.With a hose equipped with a soft flow nozzle, wash as much dirt as possible off of the filter module while it is still inside the tank. Allow tank to drain completely.

2.Make sure that the inside of the tank is clean. Lift out the module and hose it down thoroughly. Spray the en- tire module surface. Allow module to drain.

3.Inspect the module. If necessary, repeat the washing operation. If the module is damaged, replace it.

NOTICE: If this cleaning method does not remove all deposits, see “Special Cleaning Instructions” section in this manual.

4.Inspect and clean air bleed filter at top of module.

5.Follow all steps in the “Assembly” and “Initial Startup” sections of this manual.

Special Cleaning Instructions:

Use this procedure to clean scale or oils which are not re- moved by hosing down module. Be sure to dispose of spent chemicals according to all applicable codes and waste disposal ordinances. Use a soft stream nozzle to minimize flying water and spray.

Risk of fire or explosion. Isolate filter from system before chemical cleaning; rinse filter

and elements completely before returning to service. If filter cannot be isolated, remove media and clean at an- other location. Follow chemical manufacturer’s instruc- tions for use. Do not mix chemicals except as directed by manufacturer. Do not allow cleaning chemicals to mix with or to come in contact with chlorine, bromines, other chemicals, or chemical feed devices.

1.Sponge or spray the module according to chemical manufacturer’s directions.

2.If soaking is required, remove the module from the fil- ter tank and submerge it in a separate tank. Follow cleaner manufacturer’s instructions carefully.

3.After completing chemical manufacturer’s instructions, drain and rinse the module completely. Dispose of cleaners in accordance with local codes and disposal ordinances.

4.Rinse the inside of the filter tank. Drain it completely.

5.Follow instructions in the “Assembly” and “Initial Startup” sections of this manual.

Recommended Specialty Filter Cleaners

Filter Cleanse™, Great Lakes Biochemical

BIOGUARD Strip Kwik™, BIOGUARD KleenIt™,

Softswim® Filter Cleaner,** BIOLABS, Inc.

Filter Kleen™, Haviland Products Co.

BAQUA CLEAN™, ** Zeneca, Inc.

**MUST be used when using any PHMB based sanitizer.

8

Image 8
Contents System 2TM Modular DE Filter Table of Contents Owner’s Information When to Clean the FilterGeneral Information Specifications Backwash ModeFilter Specifications Normal OperationInstallation Filter Assembly Filter mount mustInitial START-UP ValvesCleaning the Filter When to CleanFilter Backwash Procedure DisassemblySafety Latch See Figure AssemblyModule Cleaning PRO- Cedure Special Cleaning InstructionsSystem Inspection WinterizingGeneral Weekly InspectionExploded View Repair Parts List Troubleshooting Guide Warranty Registration Card Filtro modular de tierra De diatomeas System 2TM Índice ¡LEA Y Siga LAS Instrucciones DE SeguridadInformación General Cuando limpiar el filtroInformación del propietario Advertencia Presión peligrosa. Para evitar leEspecificaciones Operación normalModo de retrolavado Cuadro 2 Especificaciones del filtroInstalación Arranque InicialEnsamblaje del filtro La instalación del filtro debe VálvulasProcedimiento DE Desensamblaje / Ensamblaje DEL Filtro Limpieza DEL FiltroProcedimiento de retrolavado del filtro Cuando limpiarloEnsamblaje Pasador DE Seguridad Consulte la FiguraAdvertencia Riesgo de quemaduras de índole Procedimiento DE Limpieza DEL MóduloInstrucciones especiales para la limpieza Inspección semanal Inspección DEL SIS- TemaAcondicionamiento Para EL Invierno Vista Detallada Lista DE Piezas DE Repuesto Guía Para LA Localización DE Fallas Tiempo de ciclo cortoTarjeta de registro de garantía

PLDE48, PLDE36 specifications

Pentair, a global leader in water treatment and sustainability solutions, offers a range of high-performance water filtration systems, among which the Pentair PLDE36 and PLDE48 stand out. These models are designed for both residential and commercial applications, providing reliable water filtration that ensures the quality of water used for drinking, cooking, and other household needs.

The Pentair PLDE36 and PLDE48 are equipped with advanced filtration technologies that enhance their effectiveness. One notable feature is their multi-stage filtration process, which combines sediment filtration, activated carbon filtration, and a specialized membrane to remove a wide range of contaminants from the water. This includes chlorine, sediment, heavy metals, and other harmful substances, ensuring that the output water is clean, safe, and great-tasting.

One of the key characteristics of the PLDE series is its high capacity and flow rate. The PLDE36 is capable of providing up to 36,000 gallons of filtered water, while the PLDE48 can deliver up to 48,000 gallons, making these filters suitable for larger households or small commercial operations. This high capacity reduces the need for frequent filter changes, providing convenience and cost-effectiveness for users.

Another significant aspect of these models is the ease of installation and maintenance. The Pentair PLDE systems come with user-friendly interfaces and clear instructions, allowing for straightforward setup and operation. Additionally, the filter replacement process has been simplified, ensuring customers can easily replace cartridges without requiring professional assistance.

Both the PLDE36 and PLDE48 are built with durable materials designed to withstand various environmental conditions. Their robust construction ensures longevity, which is crucial for maintaining consistent water quality over time. Additionally, these systems come equipped with monitoring features that alert users when it's time to change the filter, further simplifying maintenance.

Energy efficiency is also an integral part of the Pentair PLDE series. Utilizing smart technologies, these systems minimize power consumption while maximizing performance, aligning with the growing demand for eco-friendly solutions.

In conclusion, the Pentair PLDE36 and PLDE48 are advanced water filtration systems that combine innovative technologies, high capacity, ease of use, and sustainability. These features make them ideal choices for anyone looking to ensure access to clean, safe drinking water while also being mindful of environmental impact.