CLEANING AND CARE

CAUTION!

Before cleaning the indoor unit, be sure to turn it off and disconnect the Power Supply Cord.

● Be sure the Intake Grille (Fig. 1 a-8) is installed securely.

● When removing or replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result.

Cleaning the Intake Grille

1.Remove the Intake Grille.

1 Place your fingers at both lower ends of the grille panel, and lift forward; if the grille seems to catch partway through its movement, continue lifting up- ward to remove.

2Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal.

Intake Grille

Mounting

shaft

Knob

2. Clean with water.

Remove dust with a vacuum cleaner; wipe the indoor unit with warm water, then dry with a clean, soft cloth.

3. Replace the Intake Grille.

1 Pull the knobs all the way.

2Hold the grille horizontal and set the left and right mounting shafts into the bearings at the top of the panel.

3Press the place where the arrow on the diagram indi- cates and close the Intake Grille.

2

2

 

 

Mounting

1 3

1 3

shaft

Bearing

Knob

Cleaning the Air Filter

1. Open the Intake Grille, and remove the air filter.

Lift up the air filter’s handle, disconnect the two lower

tabs, and pull out.

Air filter (Right & Left)

 

 

 

 

 

 

Air filter handle

Hooks(two places)

2. Remove dust with a vacuum cleaner or by washing.

After washing, allow to dry thoroughly in a shaded place.

3.Replace the Air Filter and close the Intake Grille.

1 Align the sides of the air filter with the panel, and push in fully, making sure the two lower tabs are returned properly to their holes in the panel.

2 Close the Intake Grille.

Hooks(two places)

 

(For purposes of example, the illustration shows the indoor unit without Intake Grille installed.)

Dust can be cleaned from the air filter either with a vacuum cleaner, or by washing the filter in a solution of neutral detergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before rein- stalling.

If dust is allowed to accumulate on the air filter, airflow will be reduced, lowering operating efficiency and increas- ing noise.

During periods of normal use, the Air Filters should be cleaned every two weeks.

Don't operate the air conditioner with being opened the intake grille.

When used for extended periods, the indoor unit may accumulate dust inside, reducing its performance. We recommend that the indoor unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.

When cleaning the indoor unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner.

Do not expose the indoor unit’s body to liquid insecticides or hairsprays.

When shutting down the indoor unit for one month or more, first allow the fan mode to operate continuously for about one-half day to allow internal parts to dry thoroughly.

En-13

Page 14
Image 14
Friedrich MW12Y3H, MW09Y3H manual Cleaning and Care

MW09Y3H, MW12Y3H specifications

Friedrich MW09Y3H and MW12Y3H are the latest offerings in Friedrich's line of mini-split air conditioning systems, known for their efficiency, convenience, and advanced technology. These units are designed to provide optimal comfort in a wide range of environments, from residential spaces to small commercial establishments.

One of the main features of both the MW09Y3H and MW12Y3H models is their high energy efficiency rating. The seasonal energy efficiency ratio (SEER) of these systems is impressive, allowing for significant energy savings compared to traditional air conditioning units. This not only helps to lower electricity bills but also contributes to a reduced carbon footprint, making them an eco-friendly choice.

The MW09Y3H is ideal for smaller spaces, with a cooling capacity of 9,000 BTUs, making it well-suited for bedrooms or small living rooms. In contrast, the MW12Y3H offers a cooling capacity of 12,000 BTUs, providing the necessary power for larger areas. Both models utilize inverter technology, which allows the compressor to operate at variable speeds, ensuring consistent temperature control while minimizing energy consumption.

Another standout characteristic is the advanced filtration system integrated into both units. This system captures dust, allergens, and other pollutants, promoting better indoor air quality. This is particularly beneficial for individuals with allergies or respiratory conditions, as the filters can be easily removed and cleaned for maintenance.

Friedrich also emphasizes user convenience with these models. Both units come with a user-friendly remote control that allows for easy adjustments to temperature settings, fan speed, and mode selection from a distance. Additionally, the LED display on the indoor unit provides clear visibility of the current settings and temperature.

Furthermore, the MW09Y3H and MW12Y3H include a variety of operating modes, such as cooling, heating, dehumidifying, and fan-only modes, providing versatility for year-round comfort. The heat pump functionality allows these units to provide heating, making them a great choice for colder climates without the need for additional heating sources.

In summary, Friedrich's MW09Y3H and MW12Y3H mini-split air conditioning systems stand out due to their energy efficiency, advanced filtration, user-friendly controls, and versatile operating modes. They are a perfect choice for anyone seeking reliable and effective climate control solutions while prioritizing sustainability and comfort in their living spaces.