CONTENTS

SAFETY PRECAUTIONS

En-1

.........................MINIMUM HEAT OPERATION

En-11

FEATURES AND FUNCTIONS

En-2

ECONOMY OPERATION

En-11

NAME OF PARTS

En-3

SWING OPERATION

En-12

PREPARATION

En-5

COIL DRY OPERATION

En-12

OPERATION

En-6

MANUAL AUTO OPERATION

En-12

TIMER OPERATION

En-8

CLEANING AND CARE

En-13

SLEEP TIMER OPERATION

En-9

TROUBLESHOOTING

En-14

ADJUSTING THE DIRECTION OF

 

OPERATING TIPS

En-15

AIR CIRCULATION

En-10

SPECIFICATION

En-16

 

 

 

 

SAFETY PRECAUTIONS

Do not attempt to install this air conditioner by yourself.

DANGER!

This air conditioner contains no user-serviceable parts. Always consult authorized serv-

 

 

ice personnel for repairs.

 

 

When moving, consult authorized service personnel for disconnection and installa-

 

 

tion of the air conditioner.

 

 

Do not become excessively chilled by staying for many hours in the direct cooling

 

 

airflow.

 

 

Do not insert fingers or objects into the outlet port or intake grille.

 

 

Do not start and stop air conditioner operation by disconnecting the power supply

 

 

cord and so on.

 

 

Take care not to damage the power supply cord.

 

 

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn

 

 

off the breaker, and consult authorized service personnel.

 

 

If the power supply cord of this appliance is damaged, it should only be replaced by

 

 

the authorized service personal, since special purpose tools and specified cord are

 

 

required.

 

 

Provide occasional ventilation during use.

CAUTION!

Do not direct airflow at fireplaces or heating apparatus.

 

 

 

 

Do not climb on, or place objects on, the air conditioner.

 

 

Do not hang objects from the indoor unit.

 

 

Do not set flower vases or water containers on top of air conditioners.

 

 

Do not expose the air conditioner directly to water.

 

 

Do not operate the air conditioner with wet hands.

 

 

Do not pull power supply cord.

 

 

Turn off power supply when not using the indoor unit for extended periods.

 

 

Check the condition of the installation stand for damage.

 

 

Do not place animals or plants in the direct path of the airflow.

 

 

Do not drink the water drained from the air conditioner.

 

 

Do not use in applications involving the storage of foods, plants or animals, precision

 

 

equipment, or art works.

 

 

Connection valves become hot during Heating; handle with care.

 

 

Do not apply any heavy pressure to radiator fins.

 

 

Operate only with air filters installed.

 

 

Do not block or cover the intake grille and outlet port.

 

 

Ensure that any electronic equipment is at least one meter away from either the in-

 

 

door or outdoor units.

 

 

Avoid installing the air conditioner near a fireplace or other heating apparatus.

 

 

When installing the indoor and outdoor unit, take precautions to prevent access to

 

 

infants.

 

 

Do not use inflammable gases near the air conditioner.

En-1

Page 2
Image 2
Friedrich MW12Y3H, MW09Y3H manual Contents, Safety Precautions

MW09Y3H, MW12Y3H specifications

Friedrich MW09Y3H and MW12Y3H are the latest offerings in Friedrich's line of mini-split air conditioning systems, known for their efficiency, convenience, and advanced technology. These units are designed to provide optimal comfort in a wide range of environments, from residential spaces to small commercial establishments.

One of the main features of both the MW09Y3H and MW12Y3H models is their high energy efficiency rating. The seasonal energy efficiency ratio (SEER) of these systems is impressive, allowing for significant energy savings compared to traditional air conditioning units. This not only helps to lower electricity bills but also contributes to a reduced carbon footprint, making them an eco-friendly choice.

The MW09Y3H is ideal for smaller spaces, with a cooling capacity of 9,000 BTUs, making it well-suited for bedrooms or small living rooms. In contrast, the MW12Y3H offers a cooling capacity of 12,000 BTUs, providing the necessary power for larger areas. Both models utilize inverter technology, which allows the compressor to operate at variable speeds, ensuring consistent temperature control while minimizing energy consumption.

Another standout characteristic is the advanced filtration system integrated into both units. This system captures dust, allergens, and other pollutants, promoting better indoor air quality. This is particularly beneficial for individuals with allergies or respiratory conditions, as the filters can be easily removed and cleaned for maintenance.

Friedrich also emphasizes user convenience with these models. Both units come with a user-friendly remote control that allows for easy adjustments to temperature settings, fan speed, and mode selection from a distance. Additionally, the LED display on the indoor unit provides clear visibility of the current settings and temperature.

Furthermore, the MW09Y3H and MW12Y3H include a variety of operating modes, such as cooling, heating, dehumidifying, and fan-only modes, providing versatility for year-round comfort. The heat pump functionality allows these units to provide heating, making them a great choice for colder climates without the need for additional heating sources.

In summary, Friedrich's MW09Y3H and MW12Y3H mini-split air conditioning systems stand out due to their energy efficiency, advanced filtration, user-friendly controls, and versatile operating modes. They are a perfect choice for anyone seeking reliable and effective climate control solutions while prioritizing sustainability and comfort in their living spaces.