Friedrich MW09Y3H, MW12Y3H manual Adjusting The Direction Of Air Circulation, En-10

Models: MW09Y3H MW12Y3H

1 18
Download 18 pages 24.13 Kb
Page 11
Image 11
ADJUSTING THE DIRECTION OF AIR CIRCULATION

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.

Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.

Vertical Air Direction Adjustment

Press the SET button (Fig. 6 b-11).

Each time the button is pressed, the air direction range will change as follows:

RDANGER!

Never place fingers or foreign objects in- side the outlet ports, since the internal fan operates at high speed, and personal injury could be caused.

1 Types of Air flow Direction Setting:En-10 2 Manual backgroundManual background 3 Manual backgroundManual background 4 Manual backgroundManual background 5 Manual backgroundManual background 6

Types of Air flow Direction Setting:

For better heating/cooling effect, it is recommended to set the air direction in the following range.

1, 2, 3 : During Cooling/Dry modes

4, 5, 6 : During Heating mode

The Remote Control Unit’s display does

 

not change.

1

 

 

2

 

3

 

4

 

5

 

6

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry mode : Horizontal flow 1

During Heating mode

: Downward flow 6

During AUTO/HEAT mode operation, for the first one minute after beginning op- eration, airflow will be horizontal 1; the air direction cannot be adjusted during this period.

The air flow direction setting will temporarily become 1 when the temperature of the air flow is low at the start of the Heating mode.

Always use the Remote Control Unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper op- eration; in this case, stop operation and restart. The louvers should begin to operate properly again.

During use of the Cooling and Dry modes, do not set the Airflow Direc- tion Louvers in the Heating range (4 - 6) for many hours, since water vapor may condense near the outlet louvers and drops of water may drip from the indoor unit. During the Cool- ing and Dry modes, if the Airflow Di- rection Louvers are left in the heating range for more than 30 minutes, they will automatically return to position 3.

When used in a room with infants, chil- dren, elderly or sick persons, the airflow direction and room temperature should be considered carefully when making settings.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air flow in the direction you prefer.

RDANGER!

When adjusting the Right-Left Louvers, it is necessary to stop the Air-Conditioner first and make sure that it stops completely before adjusting the direction.

Right-Left Louvers

knob

knob(two places)

En-10

Page 11
Image 11