1 54
Download 54 pages 24.45 Kb
Page 20
Image 20

3.Open the plain water inlet supply line shutoff valve. Check for water leaks and tighten any loose connections.

4.Place the carbonator water pump motor power switch (located on the refrigeration assembly control box) in the “ON”position. The carbonator water pump will start and continue to operate until the carbonated water

tank has been filled, then the water pump motor will stop. Check for CO2, plain water, and carbonated wa- ter leaks and tighten any loose connections.

5.Adjust the syrup tanks CO2 regulators as instructed in SERVICE AND MAINTENANCE section of this manual.

6.Install full syrup tanks into the syrup systems.

7.Make sure keyed lock-out switch (left-side facing front of Unit) is in the “ON”(vertical) position.

8.Dispense from each dispensing valve until air is bled from the systems and until syrup and applicable plain or carbonated water are dispensed.

9.Check for syrup and water leaks and repair any leaks.

10. Install the Unit hood and secure with screw.

ADJUST WATER-TO-SYRUP “RATIO” (BRIX) OF DISPENSED PRODUCT

1.Adjust the dispensing valves for water flow rate as instructed in SERVICE AND MAINTENANCE section of this manual.

2.Adjust the dispensing valves for Water-to-Syrup “Ratio”(Brix) of dispensed product as instructed in SERVICE AND MAINTENANCE section of this manual.

3.Seal all access holes to the Unit with a silastic sealant such as Dow Corning RTV 731 or equivalent.

4.Install Unit front access panel and secure with two screws.

5.Install drip tray on the Unit.

15