UNIT OPERATION

3.Install plug in water fill hole.

4.115 VAC, 60 HZ Units.

Make sure the main power switch on right side of the Unit (see Figure 5) is in the “OFF”position. 115 VAC, 60 HZ Units and 230 VAC, 50 HZ Units.

Make sure the carbonator water pump motor power switch located on the drop-in refrigeration assembly electrical control box (see Figure 5) is in the “OFF”position.

WARNING: Unit must be electrically grounded to avoid possible fatal electrical shock or serious injury to the operator. Unit power cord is equipped with a three-prong plug. If a three-hole (grounded) electrical outlet is not available, use an approved method to ground

the Unit.

5.Plug Unit power cord into a properly grounded electrical outlet.

6.115 VAC, 60 HZ Units.

A.Plug Unit power cord into an accessible and properly grounded electrical outlet with GFCI (ground fault circuit interrupt).

B.Place Unit main power switch on right side of the Unit in the “ON”position. The compressor, condens- er fan motor, and agitator motor will start and begin forming an ice bank. When full ice bank has been formed, the compressor and condenser fan motor will stop but the agitator motor will continue to oper- ate circulating ice water bath in the water tank.

7.230 VAC, 50 HZ Units.

A.Plug Unit power cord into an accessible and properly grounded electrical outlet with ELCB (earth leakage circuit breaker). The compressor, condenser fan motor, and agitator motor will start and begin forming an ice bank. When full ice bank has been formed, the compressor and condenser fan motor will stop but the agitator motor will continue to operate circulating ice water bath in the water tank.

UNIT OPERATION

WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before

attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.

CAUTION: Before opening CO2 cylinder shutoff valve, turn secondary CO2 regulators adjusting screws to the left (counterclockwise) until all tension is relieved from adjusting screws springs.

1.Open (counterclockwise) the CO2 cylinder shutoff valve slightly to allow the lines to slowly fill with gas, then open the valve fully to back-seat the valve. (back-seating the valve prevents leakage around the valve shaft). Check for CO2 leaks.

2.Adjust CO2 regulator (regulator that controls the Unit built-in cold carbonator CO2 pressure) as instructed in the SERVICE AND MAINTENANCE section of this manual. Check for CO2 leaks and repair if evident..

312027000