SYRUP TANK SYSTEM

SYRUP TANK SYSTEM

1.Disconnect empty syrup tank from syrup system.

2.Check syrup drink quick disconnects for sticky or restricted operation. Wash disconnects in warm water.

3.Connect full tank of syrup into syrup system.

BAG-IN-BOX SYRUP SYSTEM

1.Disconnect empty bag-in-box container from syrup system.

2.Check bag-in-box connecter for sticky or restricted operation. Wash bag-in-box connecter in warm water.

3.Connect full bag-in-box container into syrup system.

SYRUP FLAVOR CHANGE

1.Perform sanitizing procedure (as instructed in this section of the manual) on the syrup system syrup flavor change will be made on.

2.Connect a new flavor syrup into the syrup system.

CLEANING CO2 SYSTEM CO2 GAS CHECK VALVES

(see applicable Figure 2 or 3 and 11)

The CO2 regulators and CO2 manifold CO2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS REPLACE BALL SEAT (QUAD RING SEAL) EACH TIME GAS CHECK VALVES ARE SERVICED.

FIGURE 11. CO2 GAS CHECK VALVE ASSEMBLY

35

312027000

 

Page 40
Image 40