OPERATOR’S INSTRUCTIONS
This section covers operating controls, daily
WARNING: Disconnect electrical power to the Unit to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service the internal components or electrical wiring.
CAUTION: Do not place or store anything on top of the Unit.
OPERATING CONTROLS
(see Figure 5)
DISPENSING VALVE LEVER
The dispensing valve lever, located on bottom of the valve, needs only to be pressed with cup or glass to dis- pense product.
DISPENSING VALVE WITH WATER LEVER
The dispensing valve water lever will dispense only water when actuated.
DISPENSING VALVES KEYED LOCK-OUT SWITCH
The dispensing valves keyed
UNIT POWER SWITCH (115 VAC, 60 HZ UNITS ONLY)
The Unit power switch, located on the right side of the Unit (see Figure 5), must be in the “ON”position before the Unit will operate.
CARBONATOR WATER PUMP MOTOR POWER SWITCH
The carbonator water pump motor power switch, located on the refrigeration assembly control box, (see Figure 5), must be in the “ON”position before the carbonator water pump motor will operate. The purpose of the power switch is to turn off the carbonator water pump motor for service and maintenance. THE WATER SUPPLY TO THE CARBONATOR WATER PUMP MUST BE TURNED ON BEFORE RESTARTING THE CARBONATOR. STARVING THE WATER PUMP OF WATER WILL DAMAGE THE PUMP.
DAILY PRE-OPERATION CHECK
1.Check CO2 cylinder regulator assembly