Pelican WF4 owner manual Chemical Injector Pump and Solution Tank Installation

Page 12

Pelican WF4/WF8 Premium Whole House Iron and Manganese

Rev R

Filtration System

Page 12

 

 

 

 

Chemical Injector Pump and Solution Tank Installation

 

Chemical Injector

Spigot

 

Pump

 

(optional)

 

 

Incoming

Chemical Injector

Outgoing Water

to House

Water

Pump Tubing

 

Supply

 

 

 

 

Pre-Filter

Nut

 

 

 

 

Pump Foot

 

 

Valve

 

35 Gallon

 

 

Solution Tank

 

Figure 7

Chemical Injector Pump Installation

!IMPORTANT!

Install the Chemical Injector Pump into the water supply after the Pre-Filter and before any other filtration or softening system.

1.Determine the size and material of your incoming water supply line from the Pre-Filter System.

2.Mount the Chemical Injector Pump to the wall using the provided brackets. Line up the inflow and outflow connections with the current water line.

3.Plumb the Chemical Injector Pump into your water line. The arrow on the body of the Chemical Injector Pump shows the correct water flow direction. The water should enter and exit the pump following the direction of the arrow.

Solution Tank Installation

1.Remove the black cap from the opening on the Solution Tank.

2.Drill one 3/8” hole into the top of the Solution Tank.

3.Insert the end of the Chemical Injector Pump Tubing with the pump foot valve connected, into the hole which was covered by the black cap on the top of the Solution Tank.

4.Feed and pull the other end of the tubing through the drilled opening on the top of the Solution Tank.

5.Fill the Solution Tank with 9 cups household bleach and 35 gallons of fresh bottled water. Replace the cap.

6.Determine the length of Chemical Injector Pump Tubing required to reach the bottom connection point of the Chemical Injector Pump and then cut the Chemical Injector Pump Tubing to the appropriate length.

7.Connect the Chemical Injector Pump Tubing to the suction valve on the Chemical Injector Pump.

!IMPORTANT!

Ensure the Chemical Injector Pump Tubing is free of kinks.

!IMPORTANT!

Ensure Solution Tank is not sitting directly on a concrete floor.

© 2013 Enviro Water Solutions, Inc.

www.pelicanwater.com

3060 Performance Circle, Suite 2, DeLand, FL 32724

(877) 842-1635

Image 12
Contents Page Rev R Table of Contents Product Operation and Specifications Important InformationComplete Parts List Parts ListAdditional fittings will be needed to adapt to your plumbing Installation Overview Pre-InstallationBypass Valve Installation Rev R Carbon Tank Soak Carbon Tank Wash Installation Pre-Filter AssemblyPre-Filter Installation Chemical Injector Pump and Solution Tank Installation Chemical Injector Pump InstallationSolution Tank Installation Iron and Manganese Tank Installation Bypass Valve FittingsWhole House Water Filter Tank Installation Part DescriptionRev R Complete the Installation Setting the ValveProgramming the Electronic Head Testing Chlorine Levels in Water Setting the ValveSetting the Time Iron and Manganese Tank RegenRev R Care and Cleaning Solution Tank Refill ChlorineSediment Filter Replacing the Sediment FilterTroubleshooting Problem SolutionWarranty Pelicans Limited Lifetime WarrantyManufacturer’s Performance Guarantee Limitations and ResponsibilitiesRev R Warranty Registration Form Pelican Warranty Registration FormSend To Plumber’s Information optionalProduct Certifications