Pelican WF4 Iron and Manganese Tank Regen, Testing Chlorine Levels in Water, Setting the Valve

Page 17

Pelican WF4/WF8 Premium Whole House Iron and Manganese

Rev R

Filtration System

Page 17

 

 

 

 

4.Follow the steps in the table below to finish setting the valve. When each setting is displayed, use the UP and DOWN buttons to scroll to the appropriate data setting displayed in the table. Press EXTRA CYCLE to select the data setting and go to the next setting.

Table 4: Setting the Valve

Parameter Display (Left Corner)

Data Display Set To

 

 

VT (Valve Type)

Fltr

 

 

CT (Control Type)

tc

 

 

DO (Day Override)

3

 

 

RT (Regeneration Time)

2:00

 

 

BW (Backwash)

10

 

 

RR (Rapid Rinse)

10

 

 

Step 2: Setting the Time

1.Press and hold down the UP button to change the clock.

2.Press the EXTRA CYCLE button when the time is set. The water valve displayed will stop flashing when the time is set.

Iron and Manganese Tank Regen

!IMPORTANT!

You will not be able to use water in the house for approximately 25 minutes during the Regen process. 1. Press and hold the EXTRA CYCLE button for 3 seconds.

Note: Gears will make noise and water will start to flow.

2. Allow the system to EXTRA CYCLE for 25 minutes.

Your manual regen cycle is complete and the tank is ready for use.

Note: The days between regen may vary based on flow and Iron content. If you are unsure about the days between regen please contact your Pelican dealer for further help.

Testing Chlorine Levels in Water

1.Put the carbon tank in bypass.

2.Turn on the nearest cold water faucet to the system.

3.Listen and watch the pump to make sure it is pumping. The pump should pulse and not run continuously. If the water is off, the pump will stop.

4.Let the water run for 10 minutes.

5.After 10 minutes, use the chlorine test strip at the running cold water faucet to check the chlorine level.

6.The optimum chlorine level reading is 3ppm on the test strip.

a.If the level is lower than 3ppm chlorine, remove the black clip from the ratio adjustment slide. Turn the ratio adjustment slide 2 full revolutions in the positive direction. Replace the black clip.

b.If it is higher than 3ppm, remove the black clip from the ratio adjustment slide. Turn the ratio adjustment slide 2 full revolutions in the negative direction. Replace the black clip.

© 2013 Enviro Water Solutions, Inc.

www.pelicanwater.com

3060 Performance Circle, Suite 2, DeLand, FL 32724

(877) 842-1635

Image 17
Contents Page Rev R Table of Contents Important Information Product Operation and SpecificationsParts List Complete Parts ListAdditional fittings will be needed to adapt to your plumbing Bypass Valve Installation Installation OverviewPre-Installation Rev R Carbon Tank Soak Carbon Tank Wash Pre-Filter Installation InstallationPre-Filter Assembly Solution Tank Installation Chemical Injector Pump and Solution Tank InstallationChemical Injector Pump Installation Bypass Valve Fittings Iron and Manganese Tank Installation Part Description Whole House Water Filter Tank InstallationRev R Programming the Electronic Head Complete the InstallationSetting the Valve Setting the Valve Testing Chlorine Levels in WaterSetting the Time Iron and Manganese Tank RegenRev R Solution Tank Refill Chlorine Care and CleaningSediment Filter Replacing the Sediment FilterProblem Solution TroubleshootingPelicans Limited Lifetime Warranty WarrantyManufacturer’s Performance Guarantee Limitations and ResponsibilitiesRev R Pelican Warranty Registration Form Warranty Registration FormSend To Plumber’s Information optionalProduct Certifications