Pelican WF4 owner manual Product Operation and Specifications, Important Information

Page 4

Pelican WF4/WF8 Premium Whole House Iron and Manganese

Rev R

Filtration System

 

 

 

Page 4

 

 

 

 

 

 

 

 

Product Operation and Specifications

 

 

 

 

 

Specification Description

WF4

 

WF8

 

 

 

 

 

Max Flow Rate*

10

GPM

 

15 GPM

 

 

 

 

 

Minimum Working Pressure

25

PSI

 

 

 

 

 

Maximum Working Pressure

80

PSI

 

 

 

 

Maximum Vacuum

5 inch/127 mm Hg

 

 

 

 

Operating Temperatures

36°F – 120°F

 

 

 

 

 

pH Range

7 - 11

 

 

 

 

 

 

 

*Minimum Rated Service Flow must be at least 6 GPM.

Important Information

Read these instructions carefully and determine the location of all system components before beginning installation.

Check all applicable plumbing, building, and electrical codes for installation compliance.

Install the system on the main water supply.

Systems that contain electronic components cannot be installed outside in uncovered areas.

WARNING:

If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or galvanized metal, the plastic components of the system will interrupt the continuity of the plumbing system. As a result any errant electricity from improperly grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing. Some homes may have been built in accordance with building codes, which actually encouraged the grounding of electrical appliances through the plumbing system. Consequently, the installation of a bypass consisting of the same material as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re- establishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use.

CAUTION:

When adding a filtration/softening system to homes/buildings supplied by well water, the system should be installed following the pressure tank. DO NOT USE this system for pneumatic or hydro pneumatic applications. If you are using a booster pump, then install this system following the booster pump. If you have questions, please call customer service.

© 2013 Enviro Water Solutions, Inc.

www.pelicanwater.com

3060 Performance Circle, Suite 2, DeLand, FL 32724

(877) 842-1635

Image 4
Contents Page Rev R Table of Contents Product Operation and Specifications Important InformationComplete Parts List Parts ListAdditional fittings will be needed to adapt to your plumbing Pre-Installation Installation OverviewBypass Valve Installation Rev R Carbon Tank Soak Carbon Tank Wash Pre-Filter Assembly InstallationPre-Filter Installation Chemical Injector Pump Installation Chemical Injector Pump and Solution Tank InstallationSolution Tank Installation Iron and Manganese Tank Installation Bypass Valve FittingsWhole House Water Filter Tank Installation Part DescriptionRev R Setting the Valve Complete the InstallationProgramming the Electronic Head Testing Chlorine Levels in Water Setting the ValveSetting the Time Iron and Manganese Tank RegenRev R Care and Cleaning Solution Tank Refill ChlorineSediment Filter Replacing the Sediment FilterTroubleshooting Problem SolutionWarranty Pelicans Limited Lifetime WarrantyManufacturer’s Performance Guarantee Limitations and ResponsibilitiesRev R Warranty Registration Form Pelican Warranty Registration FormSend To Plumber’s Information optionalProduct Certifications