GE ZEK938, ZEK958 owner manual Before You Call For Service…, Do not Work

Page 41

Save time & money!

Review the troubleshooting tips on the following pages first and you may not need to call for service.

 

 

Before You Call For Service…

 

 

 

 

 

 

 

 

Wall Oven

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

 

 

 

 

 

CLOCK AND TIMER

• A fuse in your home may be blown or the circuit breaker tripped.

 

DO NOT WORK

Replace the fuse or reset the circuit breaker.

 

 

• Oven controls improperly set. See the Oven Control, Clock and Timer

 

 

section.

 

 

 

 

 

OVEN LIGHT DOES

• Light bulb is loose or defective. Tighten or replace the bulb.

 

NOT WORK

• Pad operating light is broken. Call for service.

 

 

 

 

 

 

 

OVEN

• Oven thermostat needs adjustment. See the Adjust the Oven Thermostat

 

TEMPERATURE

Do it yourself! section.

 

TOO HOT OR

 

 

 

 

TOO COLD

 

 

 

 

 

 

 

 

OVEN WILL

• A fuse in your home may be blown or the circuit breaker tripped.

 

NOT WORK

Replace the fuse or reset the circuit breaker.

 

 

• Oven controls improperly set.

 

 

 

 

 

FOOD DOES NOT

• Oven controls improperly set. See the Baking or Roasting section.

 

BAKE OR ROAST

• Rack position is incorrect or the rack is not level.

 

PROPERLY

 

• Incorrect cookware or cookware of improper size being used.

 

 

 

 

• Oven thermostat needs adjustment. See the Adjust the Oven Thermostat

 

 

Do it yourself! section.

 

 

 

 

 

FOOD DOES NOT

• Oven controls improperly set. Make sure you press the BROIL

 

BROIL PROPERLY

HIGH/LOW pad.

 

 

• Improper rack position being used. See the Broiling guide.

 

 

• Food being cooked in a hot pan. Use the broiling pan and grid that

 

 

came with your oven. Make sure that it is cool.

 

 

• Cookware not suited for broiling. Use the broiling pan and grid that

 

 

came with your oven.

 

 

• The probe is plugged into the outlet in the oven. Remove the probe

 

 

from the oven.

 

 

• Aluminum foil used on the broiling pan and grid has nor been fitted

 

 

properly and slit as recommended.

 

 

• In some areas the power (voltage) may be low. Preheat the broil

 

 

element for 10 minutes. Broil for the longest period of time

 

 

recommended in the Broiling guide.

 

 

 

 

 

OVEN WILL NOT

• The oven temperature is too high to set a self-clean operation.

 

SELF CLEAN

Allow the oven to cool and reset the controls.

 

 

• Oven controls improperly set. See the Using the Self-Cleaning Oven

 

 

section.

 

 

• The probe is plugged into the outlet in the oven. Remove the probe

 

 

from the oven.

 

 

 

 

 

“CRACKING” OR

• This is normal. It is the sound of the metal heating and cooling

 

“POPPING” SOUND

during both cooking and cleaning functions.

 

 

 

 

 

EXCESSIVE SMOKING

• Excessive soil. Press the CLEAR/OFF pad. Open the windows to rid

 

DURING CLEAN

the room of smoke. Wait until the LOCKED light goes off.

 

CYCLE

Wipe up the excess soil and reset the clean cycle.

 

 

 

 

 

41

Image 41
Contents 27″ and 30″ Convection Wall Oven Introduction ContentsIf you need service Before using your wall ovenWrite down the model & serial numbers If you received a damaged wall oven Save time & moneyImportant Safety Notice SELF-CLEANING Oven Baking or Roasting and Broiling sections Design informationOven Light ON/OFF. Press to turn the oven lights on or off Features of your oven control, clock and timerTones Start pad Clock To set the clock Power failureTimer To reset the timer Using the timerTo cancel the timer Control lockoutTones at the end of a timed cycle Tone volume Special features of your oven controlHour Hour or clock blackout Hour shut off Special Features Sabbath Feature How to set for regular baking or roasting Using the Sabbath FeatureUsing the Sabbath Feature How to exit the Sabbath feature Before you begin… How to set the oven for baking or roastingAluminum foil Preheating and pan placementHI Broil How to set the oven for broilingComments Broiling guide for 27 ″ ovens on some modelsBroiling guide for 30 ″ ovens on some models How to set an immediate start and automatic stop Using the timed baking and roasting featuresHow to set Delayed start and automatic stop Cable Plug Probe Handles Temperature probeProper placement of the probe How to set the oven for roasting when using the probe Fan ConvectionRack BakingConvection roasting Cookware for convection cookingPaper and Plastic Metal and GlassConvection roasting guide How to set the oven for convection baking or roastingPage Using the timed features for convection cooking How to set Delayed start and automatic stop To Crisp Stale Items How to set the oven for warmingHow to set the oven for proofing Type of margarine will affect baking performance To adjust the oven thermostatDo it yourself How to set the oven for cleaning Before a clean cycleAfter a clean cycle How to delay the start of cleaningStainless steel Oven racks and convection roasting rackMetal parts Broiler pan and gridTo replace the door Lift-off oven door- removalTo remove the door Removable oven floor Oven doorOven heating elements Control panelProbe Oven light bulbsTo remove To replaceDo not Work Before You Call For Service…After a Clean Trouble- shooting tips Before You Call For Service…Wall Oven Wall Oven We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Consumer Services From the Date Original Purchase Your Monogram Wall Oven Warranty

ZEK938, ZEK958 specifications

The GE ZEK958 and ZEK938 are advanced digital relays designed for protecting and monitoring electrical power systems. These devices are part of GE's broader line of protective relays, which harness cutting-edge technology to ensure reliable performance and robust protection for critical electrical assets.

One of the main features of the GE ZEK958 and ZEK938 is their comprehensive protection capabilities. Both models offer multifunctional protection, including overcurrent, earth fault, and distance protection. They are adept at detecting and isolating potential faults, which can prevent equipment damage and enhance system reliability.

The ZEK958 model is particularly noted for its advanced communication protocols. It supports multiple communication standards, including IEC 61850, DNP3, and Modbus, allowing for seamless integration into modern substation automation systems. This connectivity capability ensures that real-time data can be shared across various systems, facilitating enhanced monitoring and control.

Conversely, the GE ZEK938 is designed for applications that require high-speed tripping and resilience in harsh environments. It caters to the needs of utilities and industries where rapid fault detection is crucial. The ZEK938 features robust housing and is rated for demanding conditions, ensuring consistent performance even in challenging environments.

Both models feature intuitive user interfaces that simplify setup and operation. They come equipped with large displays and user-friendly navigation, allowing operators to configure settings easily and access critical information without extensive training. Additionally, advanced diagnostic capabilities provide detailed fault records and event logs, enabling effective troubleshooting and maintenance.

In terms of technology, both the ZEK958 and ZEK938 utilize digital signal processing to offer superior precision and reliability. This technology helps to eliminate noise and enhance the accuracy of measurement, a critical aspect in power system protection. Furthermore, they incorporate sophisticated algorithms to differentiate between various types of faults, ensuring that the right corrective action is taken swiftly.

In summary, the GE ZEK958 and ZEK938 digital relays stand out for their robust protection features, versatile communication capabilities, and resilience in challenging conditions. They are engineered for modern electrical systems, combining advanced technology with user-friendly design to meet the demands of utility and industrial applications. With these relays, operators can achieve enhanced reliability, improved efficiency, and greater control over their electrical assets.