GE ZEK938, ZEK958 owner manual Before a clean cycle, How to set the oven for cleaning

Page 35

Using the Self-Cleaning Oven

Wall Oven

Before a clean cycle

The oven door must be closed and all controls must be set correctly for the cycle to work properly.

We recommend venting your kitchen with an open window or using a ventilation fan or hood during the first self-clean cycle.

Remove the broiler pan, broiler grid, probe, all cookware and any aluminum foil from the oven.

Gray porcelain-coated oven racks (including the offset rack) may remain in the oven during the self-cleaning cycle without being damaged. The convection roasting rack and nickel-plated oven racks (including the offset rack) may remain in the oven during the self-cleaning cycle, but they will darken and become hard to slide.

Do not use abrasives or oven cleaners. Clean the top, sides and outside of the oven door with soap and water.

Make sure the oven light bulb cover (on some models) is in place and the oven light is off.

IMPORTANT: The health of some birds is extremely sensitive to the fumes given off during the self-cleaning cycle of any oven. Move birds to another well-ventilated room.

Wipe up heavy soil on the oven bottom.

(Appearance may vary.)

On double oven models, you can set a clean cycle in both ovens at the same time. The last oven set will automatically delay its start until the end of the first oven’s clean cycle.

On double oven models, you can use timed baking in one oven and self-clean the other at the same time.

How to set the oven for cleaning

1Press the SELF CLEAN STD/LOW pad once for a 4-hour clean time or twice for a 3-hour clean time.

A 3-hour self-clean time is recommended for use when cleaning small, contained spills. A self-clean time of 4 hours or longer is recommended for a dirtier oven.

2If a time other than 4 hours or 3 hours is needed, use the number pads and enter the desired clean time.

You can change the clean time to any time between 3 hours and 5 hours, depending on how dirty your oven is.

3Press the START pad.

The door locks automatically. The display will show the clean time remaining. It will

not be possible to open the oven door until the temperature drops below the lock temperature and the LOCKED light goes off.

When the LOCKED light goes off, you will be able to open the door.

The word “LOCK” will flash and the oven control will signal if you set the clean cycle and forget to close the oven door.

To stop a clean cycle, press the CLEAR/OFF pad. When the LOCKED light goes off indicating the oven has cooled below the locking temperature, you will be able to open the door.

35

Image 35
Contents 27″ and 30″ Convection Wall Oven Introduction ContentsIf you received a damaged wall oven Save time & money Before using your wall ovenIf you need service Write down the model & serial numbersImportant Safety Notice SELF-CLEANING Oven Baking or Roasting and Broiling sections Design informationOven Light ON/OFF. Press to turn the oven lights on or off Features of your oven control, clock and timerTones Start pad Clock To set the clock Power failureTimer Control lockout Using the timerTo reset the timer To cancel the timerTones at the end of a timed cycle Tone volume Special features of your oven controlHour Hour or clock blackout Hour shut off Special Features Sabbath Feature How to set for regular baking or roasting Using the Sabbath FeatureUsing the Sabbath Feature How to exit the Sabbath feature Before you begin… How to set the oven for baking or roastingAluminum foil Preheating and pan placementHI Broil How to set the oven for broilingComments Broiling guide for 27 ″ ovens on some modelsBroiling guide for 30 ″ ovens on some models How to set an immediate start and automatic stop Using the timed baking and roasting featuresHow to set Delayed start and automatic stop Cable Plug Probe Handles Temperature probeProper placement of the probe How to set the oven for roasting when using the probe Baking ConvectionFan RackMetal and Glass Cookware for convection cookingConvection roasting Paper and PlasticConvection roasting guide How to set the oven for convection baking or roastingPage Using the timed features for convection cooking How to set Delayed start and automatic stop To Crisp Stale Items How to set the oven for warmingHow to set the oven for proofing Type of margarine will affect baking performance To adjust the oven thermostatDo it yourself How to set the oven for cleaning Before a clean cycleAfter a clean cycle How to delay the start of cleaningBroiler pan and grid Oven racks and convection roasting rackStainless steel Metal partsTo replace the door Lift-off oven door- removalTo remove the door Control panel Oven doorRemovable oven floor Oven heating elementsTo replace Oven light bulbsProbe To removeDo not Work Before You Call For Service…After a Clean Trouble- shooting tips Before You Call For Service…Wall Oven Wall Oven We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Consumer Services From the Date Original Purchase Your Monogram Wall Oven Warranty

ZEK938, ZEK958 specifications

The GE ZEK958 and ZEK938 are advanced digital relays designed for protecting and monitoring electrical power systems. These devices are part of GE's broader line of protective relays, which harness cutting-edge technology to ensure reliable performance and robust protection for critical electrical assets.

One of the main features of the GE ZEK958 and ZEK938 is their comprehensive protection capabilities. Both models offer multifunctional protection, including overcurrent, earth fault, and distance protection. They are adept at detecting and isolating potential faults, which can prevent equipment damage and enhance system reliability.

The ZEK958 model is particularly noted for its advanced communication protocols. It supports multiple communication standards, including IEC 61850, DNP3, and Modbus, allowing for seamless integration into modern substation automation systems. This connectivity capability ensures that real-time data can be shared across various systems, facilitating enhanced monitoring and control.

Conversely, the GE ZEK938 is designed for applications that require high-speed tripping and resilience in harsh environments. It caters to the needs of utilities and industries where rapid fault detection is crucial. The ZEK938 features robust housing and is rated for demanding conditions, ensuring consistent performance even in challenging environments.

Both models feature intuitive user interfaces that simplify setup and operation. They come equipped with large displays and user-friendly navigation, allowing operators to configure settings easily and access critical information without extensive training. Additionally, advanced diagnostic capabilities provide detailed fault records and event logs, enabling effective troubleshooting and maintenance.

In terms of technology, both the ZEK958 and ZEK938 utilize digital signal processing to offer superior precision and reliability. This technology helps to eliminate noise and enhance the accuracy of measurement, a critical aspect in power system protection. Furthermore, they incorporate sophisticated algorithms to differentiate between various types of faults, ensuring that the right corrective action is taken swiftly.

In summary, the GE ZEK958 and ZEK938 digital relays stand out for their robust protection features, versatile communication capabilities, and resilience in challenging conditions. They are engineered for modern electrical systems, combining advanced technology with user-friendly design to meet the demands of utility and industrial applications. With these relays, operators can achieve enhanced reliability, improved efficiency, and greater control over their electrical assets.