1 Before You Start

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Before initial use, or after transport, or after storage in humid or semi-hu- mid environments, or anytime the instrument has not been energized for more than 10 days, the instrument needs to be energized for a "dry-out" period of 2 hours before it can be assumed to meet all of the safety re- quirements of the IEC 1010-1. If the product is wet or has been in a wet environment, take necessary measures to remove moisture prior to apply- ing power such as storage in a low humidity temperature chamber operat- ing at 50 degree centigrade for 4 hours or more.

DO NOT operate high temperature baths (500°C) near flammable materi- als. Extreme temperatures could ignite the flammable material.

Overhead clearance is required. Do not place the instrument under a cabi- net or other structure. Always leave enough clearance to allow for safe and easy insertion and removal of probes.

The instrument is intended for indoor use only.

BURN HAZARD

Extremely cold temperatures may be present in this equipment. Freezer burns and frostbite may result if personnel fail to observe safety precau- tions.

High temperatures may be present in this equipment. Fires and severe burns may result if personnel fail to observe safety precautions.

ELECTRICAL HAZARD

These guidelines must be followed to ensure that the safety mechanisms in this instrument will operate properly. This instrument must be plugged into a 115 VAC, 60Hz (230 VAC, 50Hz optional), AC only electric outlet. The power cord of the instrument is equipped with a three-pronged grounding plug for your protection against electrical shock hazards. It must be plugged directly into a properly grounded three-prong receptacle. The receptacle must be installed in accordance with local codes and ordi- nances. Consult a qualified electrician. DO NOT use an extension cord or adapter plug.

DO use a ground fault interrupt device. This unit contains a liquid. A ground fault device is advised in case liquid is present in the electrical system and could cause an electrical shock.

Always replace the power cord with an approved cord of the correct rat- ing and type. If you have questions, contact Kaye Customer Service.

3

Image 11
Contents GE Kaye World Headquarters Table of Contents Controller Operation Parts and ControlsGeneral Operation Digital Communication Interface Maintenance Trouble ShootingWiring Diagram Figures Tables Before You Start Symbols UsedCanadian Standards Association Safety InformationBurn Hazard Bath Fluids Cold Baths World Headquarters Customer Service InformationIntroduction Environmental Conditions SpecificationsAfter-Warranty Repairs Hardware Warranty and AssistanceInstrument Warranty In-Warranty RepairsCustomer Site Assistance Equipment Maintenance AgreementsCustomer Support Customer Support AgreementSet-up Quick StartUnpacking Setting the Temperature PowerAccess set-point selection Set-point 1, 25.0C currently used Dry-out Period InstallationDrain Valve Installation Instructions Bath EnvironmentFilling With Fluid Necessary Bath Use GeneralComparison Calibration Calibration of Multiple Probes Control Panel Parts and ControlsBack Panel Bath Tank and LidBack Panel Viscosity Temperature RangeGeneral Operation Bath FluidElectrical Resistivity SafetyThermal Conductivity Thermal ExpansionEthanol CostCommonly Used Fluids Water DistilledSilicone Oil Dow Corning 200.05, 200.10 Fluid Characteristics TableMineral Oil Table of Various Bath Fluids Limitations and DisclaimerRefrigeration StirringHeater Important Refrigerant Information Temperature ControllerOperation General Operation Programmable Set-points Bath TemperatureTemperature Set-point Controller OperationDisplay Temperature Set-point Value Temperature Scale UnitsScan Rate ScanScan Control Proportional Band Heater PowerSecondary Menu New proportional band setting CO= 80C CutoutLow Limit Controller ConfigurationOperating Parameters High LimitCooling Serial Interface ParametersSample Period Duplex ModeBaud Rate Linefeed Calibration ParametersDelta Hard Cutout11.2 R0 AlphaSerial Communications Digital Communication InterfaceIBM PC and Compatibles WiringSetup RS-232 Cable Wiring forSample Period Interface CommandsDuplex Mode Serial OperationSecondary Menu Lfeed=on Lf=on Calibration Calibration ProcedureCalibration Procedure Calibration EquipmentCalibration Procedure Maintenance Maintenance Troubleshooting Trouble ShootingEMC Directive Low Voltage Directive SafetyCE Comments Revisions Wiring Diagram

CTR 80 specifications

The GE CTR 80 is an advanced technology system that has redefined efficiency and reliability in the realm of industrial control systems. Developed by General Electric, this system is tailored for various sectors, including manufacturing, energy production, and process management. Its design emphasizes modernity and innovation, making it a superior choice for companies aiming to optimize operations.

One of the main features of the GE CTR 80 is its robust control architecture. This architecture leverages a distributed control system (DCS) model, allowing for decentralized operation while maintaining central oversight. This structure enhances reliability by reducing the chances of system failures, and it enables quick local responses to changing operational conditions, ensuring minimal downtime.

The GE CTR 80 integrates cutting-edge technologies, such as advanced data analytics and machine learning algorithms. These technologies provide real-time insights into equipment performance and operational efficiency, facilitating predictive maintenance and proactive decision-making. The built-in analytics capabilities help operators identify trends and potential issues before they escalate into critical problems, significantly lowering operational risks.

The system is equipped with a user-friendly interface that promotes ease of use and navigation. Operators can quickly access various parameters and performance metrics through intuitive dashboards. Furthermore, customizable alerts and notifications ensure that operators receive timely information about any irregularities in system performance, enabling swift interventions when necessary.

Another notable characteristic of the GE CTR 80 is its seamless integration with existing systems. It supports open communication protocols, making it compatible with various sensors and devices, which is essential for organizations looking to upgrade their current infrastructure without overhauling their entire setup. This adaptability makes the CTR 80 an ideal solution for industries undergoing digital transformations and seeking to enhance connectivity.

Moreover, the GE CTR 80 is built with security as a priority. It features robust cybersecurity measures to protect data integrity and prevent unauthorized access, ensuring that operational data remains confidential and secure from potential threats.

In summary, the GE CTR 80 is a powerful industrial control system that combines reliability, advanced analytics, user-friendly functionality, and robust security features. Its versatility and adaptability make it a preferred choice for modern industrial applications, driving operational excellence and enhancing productivity across various sectors.