GE DH2000 operation manual 1PH

Page 13

Installation

Electrical Connections

Field Conversion from 3-phase to 1-phase Operation

A standard 3-phase operation dishwasher can be converted for

1-phase operation with the installation of a jumper wire on the main terminal and rewiring of the wash tank and booster tank heaters.

A jumper wire, jumper bars and a new data plate are stowed on top of the wash tank heater junction box.

To convert the dishwasher from 3-phase to 1-phase operation:

Install Main Terminal Block Jumper Wire

1.Disconnect all power to the machine.

2.Remove the top-mounted control cabinet cover and locate the main terminal block located in the left-rear corner of the cabinet.

3.Connect the jumper wire (shipped inside the control cabinet) between L2 and L3 on the output side of the main terminal block.

4.Connect the 1-phase incoming power supply to L1 and L2 on the input side of the main terminal block.

Rewire Wash Tank Heater Element for 1PH

1.Remove the lower front panel.

2.Remove the wash tank heater junction box cover.

3.Remove the paper insulator and jumper bars from the heater terminals.

4.Additional short jumper bars are stowed with the new data plate.

5.Reposition the jumper bars for 1PH as shown below.

6.Connect the #33 wire to one element terminal as shown.

7.Connect the #34 and #35 wires to the other terminals as shown.

8.Reinstall the paper insulator and the junction box cover.

SINGLE PHASE

POWER CONNECTION

208-240V/60/1

LINE IN

GRD L1 L2

L1

L2

L3

JUMPER

Connect the jumper wire between L2 and L3 on the output side of the main terminal block

 

L1

 

 

 

33

 

L1

 

L2

 

 

34

 

33

3PH

L3

 

L2

35

 

 

1PH

L3

34

 

 

35

 

Rewire Booster Heater Element for 1PH

1.Remove the booster heater element cover.

2.Remove the paper insulator and jumper bars from the heater terminals.

3.Install the jumper bars for 1PH as shown below.

4.Additional short jumper bars are stowed with the new data plate.

5.Connect the #36 wire to one element terminal as shown.

6.Connect the #37 and #38 wires to the other terminals as shown.

7.Reinstall the paper insulator and the booster heater element cover.

3PH

L3

1PH

 

38

 

37

36

38

 

36

L2

L1

 

 

 

 

 

 

L3

37

L1

 

 

 

L2

 

NOTE: The additional jumper bars needed for 1PH operation are stowed with the new data plate on top of the wash tank heater junction box.

ATTENTION:

Affix the new data plate on top of the existing machine data plate to complete the conversion.

5

Image 13
Contents Model 2000 Series Manual P/N 114614 rev. JNational Service Department Register Your Product Online Model Serial # Product Registration By FAXRevision History Limited Warranty Table of Contents Model Description Installation Receiving Converting Straight-through Operation to Corner Operation Wall Electrical Connections Three Phase Operation1PH Drain Connection Hot Water ConnectionChemical Dispenser Provisions Vent Fan ControlInstallation Check List Normal Operation Mode Final Rinse Temperature Wash Temperature 180-195F 82-91C20-25 PSI Final Rinse Pressure 150F/66CAutomatic Drain Cycle Rinse Sentry Operation ModeAfter Each Meal Period or every 8 Hours of Operation CleaningPaper Clip De-liming Daily Maintenance MaintenanceWeekly Maintenance Condition Cause Solution Service Replacement Parts Wash Pump/Motor Assembly Part Description Qty 622 JUMPER, Strip spares used for conversion Control Panel Assembly Control Panel Assembly 2815 3324 Wash and Rinse Spray Arm Assemblies Hood and Door Assembly Hood and Door Assembly Track Assemby Track Assembly 24 23 JUMPER, Strip spare for conversrion Dish Racks, Line Strainer, PRV Dish Racks, Line Strainer, PRV Timer Chart Electrical Schematic Timer Chart, Electrical SchematicSeconds Total Cycle Phase

DH2000 specifications

The GE DH2000 is a powerful and versatile gas turbine engine developed by General Electric, renowned for its high efficiency and reliability. As part of GE’s advanced hybrid technology lineup, the DH2000 is designed to cater to various applications, particularly in the power generation and industrial sectors.

One of the primary features of the GE DH2000 is its advanced aerodynamic design. The engine utilizes a high-efficiency compressor system, which enhances overall performance while reducing fuel consumption. This feature is essential in today’s energy-conscious world, where businesses are looking to minimize operational costs while meeting growing energy demands.

The DH2000 incorporates cutting-edge materials and manufacturing techniques, including advanced ceramic matrix composites and single-crystal superalloys. These materials provide excellent thermal resistance, allowing the engine to operate at higher temperatures, which directly contributes to improved efficiency. This design philosophy not only maximizes power output but also extends the lifespan of critical components.

In terms of technology, the GE DH2000 leverages digital solutions for monitoring and optimization. Its integrated control system allows real-time diagnostics and predictive maintenance, which are crucial for minimizing downtime and ensuring smooth operations. This digital capability enhances the engine's responsiveness and adaptability to changing load demands.

Moreover, the DH2000 features a modular design, which simplifies maintenance and repair processes. This modularity ensures shorter turnaround times during maintenance schedules, thus optimizing the overall operational efficiency of the system.

One of the standout characteristics of the GE DH2000 is its environmental performance. The engine is designed to meet stringent emissions regulations, ensuring that it produces minimal environmental impact. The incorporation of advanced combustion technologies reduces nitrogen oxides and carbon monoxide emissions, contributing to a cleaner operational footprint.

Finally, the GE DH2000’s versatility allows it to be utilized in various settings, from combined cycle power plants to industrial applications. With its robust performance, high efficiency, and flexible operation, the DH2000 is poised to meet the challenges of modern energy requirements while paving the way for a sustainable future. In conclusion, the GE DH2000 is a cutting-edge gas turbine engine that embodies innovation and efficiency, making it a preferred choice for industries seeking reliable and environmentally friendly power solutions.