Greenheck Fan GB manual Options and Accessories, Roof Curbs

Page 10

Options and Accessories

Roof Curbs

Prefabricated roof curbs reduce installation time and costs by ensuring compatibility between the fan, the curb and roof opening.. All curbs are insulated with fiberglass. A wide variety of roof curbs are available, including: flanged, pitched and sound-absorbing..

Hinged Curb Cap with Cables (Field Installed)

Mounted to the curb cap, allows entire fan to tilt away from curb for access to wheel and ductwork. Includes restraint cables..

Hinged Base (Factory Mounted)

Allows for easy maintenance.. Hinge and restraining cables are factory mounted to a subbase attached directly to curb without additional height added..

Curb Seal

Rubber seal between fan and curb to assure proper sealing when attached to a curb.

Curb Extensions

Extensions raise the fan discharge above the roofline and provide an accessible mounting

location for dampers.. Insect screen

bases, constructed with a removable fine mesh, are recommended for applications where insect entry must be prevented..

10

High Wind and Severe Duty Roof Curbs

Provided as an option with models G and GB. The severe-duty roof curb models can ship separately to allow for final finishing of the roof prior to the fan arrival and installation..

Model GPF This roof curb is used on fan models G/GB and specifically designed for high wind applications up to 75 psf.. Curbs are minimum

18 gauge construction in a standard height of

12 inches (305 mm), with fully-welded straight sides and a 5-inch flashing flange.. GPF is available up to 24 inches (460 mm) in height to meet greater height requirements..

Models SD and SDP These severe-duty curbs for fan models G and GB are specifically designed for high wind applications up to 150 mph, maximum design load of 130 psf.. Model SD is for use on

flat roofs and model SDP for pitched roofs.. They are attached directly to the building structure with extremely high structural design load requirements.. The severe duty curbs are 12 gauge coated steel with a 134-inch lip on the top and a 4-inch flange on the bottom.. Available heights include 12–24 inches.. Heights greater than 18 inches are reinforced in the interior with 12 gauge x 2-inch angles.

Mounting details for the roof curb to the roof substrate and the fan to the curb are included with each model G and GB installation manual..

For additional information refer to the Greenheck High Wind brochure.

Tie-Down Points

Four brackets located on the shroud for securing the fan in high wind applications.. Cables and anchors by others..

Image 10
Contents Centrifugal Roof Downblast Exhaust Fans Codes and Certifications Models G and GBModel Comparison Construction Features Models G and GBModel GB Belt Drive Emergency Smoke Control GB Problems after a seismic eventApplications Seismic G and GBHigh Wind and Hurricane G and GB Vari-GreenMotor Model G Constant Volume Load ShapeOptions HypotheticalVari-GreenControls Demand Control VentilationOptions and Accessories Roof CurbsSpeed Controllers for Standard Motors General Clean Air figure Typical InstallationsWheel Rotation Fan Inlet Connections GB 240 HP VG/5/AModel Number Code 060 G-065 Roof Downblast Exhaust Direct DriveRPM 070 G-075 080 G-085 090 G-095 Maximum BHP AT a Given RPM = RPM/33713 Roof Downblast Exhaust Belt & Direct DriveGB-071 G-097 Maximum Motor Frame Size =GB-081 G-098 Maximum BHP AT a Given RPM = RPM/29853GB-091 G-099 Maximum BHP AT a Given RPM = RPM/27033GB-101 G-103 Maximum BHP AT a Given RPM = RPM/25933 Maximum RPM =GB-101HP G-103HP Maximum BHP AT a Given RPM = RPM/31653GB-121 G-123 Maximum BHP AT a Given RPM = RPM/21703 Maximum RPM =GB-131 G-133 Maximum BHP AT a Given RPM = RPM/20473Maximum BHP AT a Given RPM = RPM/16763 GB-141 G-143Maximum Motor Frame Size = 145T GB-141HP G-143HP Maximum BHP AT a Given RPM = RPM/23513GB-161 G-163 Maximum BHP AT a Given RPM = RPM/1355GB-161HP Roof Downblast BeltExhaustDrive SizeBelt-Drive GB H-GBMaximum BHP AT a Given RPM = RPM/1708 Maximum BHP AT a Given RPM = RPM/1149 GB-180 G-183Maximum Motor Frame Size = 184T GB-180HP Roof Downblast Exhaust Belt DriveMaximum BHP AT a Given RPM = RPM/1325 GB-200 G-203 Maximum BHP AT a Given RPM = RPM/938GB-220HP Maximum BHP AT a Given RPM = RPM/1106GB-220 Maximum BHP AT a Given RPM = RPM/782Maximum BHP AT a Given RPM = RPM/838 GB-240 Maximum BHP AT a Given RPM = RPM/715GB-240HP Maximum BHP AT a Given RPM = RPM/845GB-260 Maximum BHP AT a Given RPM = RPM/572GB-300 Maximum BHP AT a Given RPM = RPM/517GB-300HP Maximum BHP AT a Given RPM = RPM/613Maximum BHP AT a Given RPM = RPM/405 GB-330Maximum Motor Frame Size = 215T GB-360 Maximum BHP AT a Given RPM = RPM/394GB-360HP Maximum BHP AT a Given RPM = RPM/431GB-420 GB-480 Maximum BHP AT a Given RPM = RPM/245GB-500 Maximum Motor Frame Size = 256TGB-540 Maximum BHP AT a Given RPM = RPM/202Vari-GreenMotor Specification SpecificationsVari-GreenControls Specification Direct Drive Specifications Model GDirect Drive, Severe Duty Specifications High Wind SpecificationsBelt Drive Specifications Model GBBelt Drive, Severe Duty Specifications Smoke Control Specifications101HP 5-10 103HP 121 071-091097 5-10 101 123