Greenheck Fan manual Construction Features, Models G and GB

Page 4

Construction Features

Models G and GB

Standard Construction Features

1Wheel

An aluminum, backward-inclined, non-overloading centrifugal wheel is utilized to generate high-efficiency and minimal sound.. Wheel cones are carefully matched to the venturi for maximum efficiency. Each wheel is robotically welded and statically and dynamically balanced for long life and quiet operation..

2

Disconnect

NEMA-1 switch is factory mounted and wiring is provided from the motor as standard

(other switches are available). All wiring and electrical components comply with the

Switch

 

National Electrical Code® (NEC) and are either UL Listed or Recognized.

 

 

3

 

Precisely sized, ground and polished so the first critical speed is at least 25% over

Fan Shaft

the maximum operating speed. Where the shaft makes contact with bearings, tight

 

 

tolerances result in longer bearing life..

4

Bearings

100% factory tested and designed specifically for air handling applications with a

minimum L10 life in excess of 100,000 hours (L 50 life of 500,000 hours)..

 

 

5

Motor

Carefully matched to the fan load and is mounted out of the airstream..

 

 

 

6

Motor Cover

Constructed of aluminum, machine-punched, and attached with fasteners that provide

for easy removal and access to motor compartment and drive assembly..

 

 

 

 

Cooling fins located on top of the fan wheel draw outside air through a large space

7Motor Cooling between the fan shroud and the motor cover directly into the motor compartment. Positive motor cooling with fresh air results in maximum motor life.

8Lifting Points Various lifting points are located on the drive frame and bearing plate (on select sizes).

9True Vibration Vibration isolators, with no metal-to-metal contact, support the drive assembly and

Isolation wheel for long life and quiet operation.

10

Drive Assembly

Belts, pulleys, and keys are oversized 150% of driven horsepower. Machined cast

pulleys are adjustable for final system balancing.. Belts are static-free and oil-resistant..

 

 

 

 

 

11

Lower Windband

Heavy-gauge aluminum with formed edges for added strength and provides

weather resistance.

 

 

12

Curb Cap

Curb cap (with integral deep spun venturi) is constructed of aluminum and is one-piece

for a weather-tight fit.

 

 

 

 

 

13Internal Conduit A large diameter conduit for installing electrical wiring through the curb cap into the motor compartment..Chase

14

Nameplate

Permanent stamped aluminum plate for exact model and serial number identification..

 

 

 

15

Galvanized

Rigid wire protects the fan discharge from birds and small objects.

Birdscreen

 

 

16

Fan Shroud

One-piece, heavy-gauge aluminum with a rolled bead for extra strength directs

exhaust air downward.

 

 

17

Mounting Holes

Curb cap has prepunched mounting holes to ensure correct attachment to the roof..

 

 

 

High Wind Construction Features

18Internal Supports

Heavy-gauge supports and bracing are added for additional strength to withstand a wind of 150 mph (75 psf)..

19

Reinforced

High wind fans include additional reinforcement for maximum strength.

Wind Band

 

 

 

 

 

 

Roof Curb

High wind load fans are certified for use with Greenheck model SD, SDP, GPF or

 

equivalent in high wing applications. Roof curbs ship separate for field installation

 

(page 10)

 

with attachment details provided.

 

 

 

 

 

4

Image 4
Contents Centrifugal Roof Downblast Exhaust Fans Codes and Certifications Models G and GBModel Comparison Construction Features Models G and GBModel GB Belt Drive Problems after a seismic event ApplicationsEmergency Smoke Control GB Seismic G and GBHigh Wind and Hurricane G and GB Constant Volume Load Shape OptionsVari-GreenMotor Model G HypotheticalVari-GreenControls Demand Control VentilationOptions and Accessories Roof CurbsSpeed Controllers for Standard Motors General Clean Air figure Typical InstallationsWheel Rotation Fan Inlet Connections GB 240 HP VG/5/AModel Number Code 060 G-065 Roof Downblast Exhaust Direct DriveRPM 070 G-075 080 G-085 090 G-095 Roof Downblast Exhaust Belt & Direct Drive GB-071 G-097Maximum BHP AT a Given RPM = RPM/33713 Maximum Motor Frame Size =GB-081 G-098 Maximum BHP AT a Given RPM = RPM/29853GB-091 G-099 Maximum BHP AT a Given RPM = RPM/27033GB-101 G-103 Maximum BHP AT a Given RPM = RPM/25933 Maximum RPM =GB-101HP G-103HP Maximum BHP AT a Given RPM = RPM/31653GB-121 G-123 Maximum BHP AT a Given RPM = RPM/21703 Maximum RPM =GB-131 G-133 Maximum BHP AT a Given RPM = RPM/20473Maximum BHP AT a Given RPM = RPM/16763 GB-141 G-143Maximum Motor Frame Size = 145T GB-141HP G-143HP Maximum BHP AT a Given RPM = RPM/23513GB-161 G-163 Maximum BHP AT a Given RPM = RPM/1355GB-161HP Roof Downblast BeltExhaustDrive SizeBelt-Drive GB H-GBMaximum BHP AT a Given RPM = RPM/1708 Maximum BHP AT a Given RPM = RPM/1149 GB-180 G-183Maximum Motor Frame Size = 184T GB-180HP Roof Downblast Exhaust Belt DriveMaximum BHP AT a Given RPM = RPM/1325 GB-200 G-203 Maximum BHP AT a Given RPM = RPM/938GB-220HP Maximum BHP AT a Given RPM = RPM/1106GB-220 Maximum BHP AT a Given RPM = RPM/782Maximum BHP AT a Given RPM = RPM/838 GB-240 Maximum BHP AT a Given RPM = RPM/715GB-240HP Maximum BHP AT a Given RPM = RPM/845GB-260 Maximum BHP AT a Given RPM = RPM/572GB-300 Maximum BHP AT a Given RPM = RPM/517GB-300HP Maximum BHP AT a Given RPM = RPM/613Maximum BHP AT a Given RPM = RPM/405 GB-330Maximum Motor Frame Size = 215T GB-360 Maximum BHP AT a Given RPM = RPM/394GB-360HP Maximum BHP AT a Given RPM = RPM/431GB-420 GB-480 Maximum BHP AT a Given RPM = RPM/245GB-500 Maximum Motor Frame Size = 256TGB-540 Maximum BHP AT a Given RPM = RPM/202Vari-GreenMotor Specification SpecificationsVari-GreenControls Specification Direct Drive Specifications Model GDirect Drive, Severe Duty Specifications High Wind SpecificationsBelt Drive Specifications Model GBBelt Drive, Severe Duty Specifications Smoke Control Specifications071-091 097 5-10 101101HP 5-10 103HP 121 123