Greenheck Fan manual Codes and Certifications, Models G and GB

Page 2

Models G and GB

Spun Aluminum • Downblast

Centrifugal Roof Exhaust Fans

Contents

 

 

 

Performance and Dimensions:

 

Model Comparison

 

. . . . . . . .3 . . .

Models G-060-095

. .

. . . .14.-17. . . .

Construction Features

 

. . . . . . . . . 4-.5 . .

Models G-097-G203

. . . . .18.-31.

.

 

 

 

 

 

Emergency Smoke Control

 

 

. . . 6

GB-071-200

. . . . . . . 18.-32

. . . . . . . .

 

 

. . . . .33.-46.

 

 

 

 

Models GB-220-540

Seismic

.

. . .

. . . . 6

 

 

 

 

 

 

 

Specifications:

 

 

 

High Wind & Hurricane

. .

. . . . . . . 7. . .

 

Vari-Green™ Motors and Controls

. .47.

 

 

 

 

 

Vari-Green™ Motor and Controls. . .

. . . .8-9. .

 

Direct Drive

. .

. . . . .48

Demand Control Ventilation .

. . . . . . . . . . .9

 

High Wind & Hurricane, Seismic G Fan. . 49

 

 

 

 

 

Roof Curbs, Options, Accessories

. . . 10.-11

 

Belt Drive

.

. . . . . 50

 

High Wind & Hurricane,

 

 

Typical Installations

. . . .

. . 12.-13. . .

 

 

 

 

Seismic & Smoke Control GB Fan. . .

. 51. .

Model Number Code

. . . .

. . . 13. . .

.Quick. . Build Programs

. .

. . . . . . . 52

 

 

 

 

Warranty

.

. . . . . 52

 

 

 

 

 

 

 

 

 

Codes and Certifications

Greenheck Fan Corporation certifies that the Models G and GB fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.. The certified ratings for Models G and GB are shown on pages 14 - 46..

G and GB models are listed for electrical (UL/cUL 705) File no.. E40001

GB models for Emergency Smoke Control Systems (UL/cUL Listed for 500˚F (260˚C) for 4 hours and 1,000˚F (538˚C) for 15 minutes) File no.. MH17511

*UL/cUL is optional and must be specified

High Wind Certification

Seismic Certification

Miami-Dade NOA for high wind and hurricane zones

OSHPD No. 0148-10 - Office of Statewide Health

 

Planning and Development (California)

 

IBC 2006 and 2009 - International Building Code

Image 2
Contents Centrifugal Roof Downblast Exhaust Fans Codes and Certifications Models G and GBModel Comparison Construction Features Models G and GBModel GB Belt Drive Emergency Smoke Control GB Problems after a seismic eventApplications Seismic G and GBHigh Wind and Hurricane G and GB Vari-GreenMotor Model G Constant Volume Load ShapeOptions HypotheticalVari-GreenControls Demand Control VentilationOptions and Accessories Roof CurbsSpeed Controllers for Standard Motors Wheel Rotation Typical InstallationsGeneral Clean Air figure Model Number Code GB 240 HP VG/5/AFan Inlet Connections RPM Roof Downblast Exhaust Direct Drive060 G-065 070 G-075 080 G-085 090 G-095 Maximum BHP AT a Given RPM = RPM/33713 Roof Downblast Exhaust Belt & Direct DriveGB-071 G-097 Maximum Motor Frame Size =GB-081 G-098 Maximum BHP AT a Given RPM = RPM/29853GB-091 G-099 Maximum BHP AT a Given RPM = RPM/27033GB-101 G-103 Maximum BHP AT a Given RPM = RPM/25933 Maximum RPM =GB-101HP G-103HP Maximum BHP AT a Given RPM = RPM/31653GB-121 G-123 Maximum BHP AT a Given RPM = RPM/21703 Maximum RPM =GB-131 G-133 Maximum BHP AT a Given RPM = RPM/20473Maximum Motor Frame Size = 145T GB-141 G-143Maximum BHP AT a Given RPM = RPM/16763 GB-141HP G-143HP Maximum BHP AT a Given RPM = RPM/23513GB-161 G-163 Maximum BHP AT a Given RPM = RPM/1355Maximum BHP AT a Given RPM = RPM/1708 Roof Downblast BeltExhaustDrive SizeBelt-Drive GB H-GBGB-161HP Maximum Motor Frame Size = 184T GB-180 G-183Maximum BHP AT a Given RPM = RPM/1149 Maximum BHP AT a Given RPM = RPM/1325 Roof Downblast Exhaust Belt DriveGB-180HP GB-200 G-203 Maximum BHP AT a Given RPM = RPM/938GB-220HP Maximum BHP AT a Given RPM = RPM/1106GB-220 Maximum BHP AT a Given RPM = RPM/782Maximum BHP AT a Given RPM = RPM/838 GB-240 Maximum BHP AT a Given RPM = RPM/715GB-240HP Maximum BHP AT a Given RPM = RPM/845GB-260 Maximum BHP AT a Given RPM = RPM/572GB-300 Maximum BHP AT a Given RPM = RPM/517GB-300HP Maximum BHP AT a Given RPM = RPM/613Maximum Motor Frame Size = 215T GB-330Maximum BHP AT a Given RPM = RPM/405 GB-360 Maximum BHP AT a Given RPM = RPM/394GB-360HP Maximum BHP AT a Given RPM = RPM/431GB-420 GB-480 Maximum BHP AT a Given RPM = RPM/245GB-500 Maximum Motor Frame Size = 256TGB-540 Maximum BHP AT a Given RPM = RPM/202Vari-GreenControls Specification SpecificationsVari-GreenMotor Specification Direct Drive Specifications Model GDirect Drive, Severe Duty Specifications High Wind SpecificationsBelt Drive Specifications Model GBBelt Drive, Severe Duty Specifications Smoke Control Specifications101HP 5-10 103HP 121 071-091097 5-10 101 123